Resistance (Ohms)
Range
Resolution
Accuracy
400.0 W
4.000 kW
40.00 kW
400.0 kW
4.000 MW
±(0.8%rdg + 6dgts)
±(0.6%rdg + 4dgts)
±(1.0%rdg + 4dgts)
Open Circuit Voltage : 0.4V DC typical
40.00 MW
±(2.0%rdg + 4dgts)
Audible Continuity Tester
Open Circuit Voltage : 0.4V DC typical
Range : 400.0W
; Accuracy : 1.5% + 8d
Audible threshold : between 10W
& 120W
.
Diode Tester
Open Circuit Voltage :
Test Current : 0.4mA typical
Capacitance
1)
Range
Resolution
2) 3)
Accuracy
500.0 nF
5.000m
F
50.00 m
F
500.0m
F
3000 m
F
±(3.5%rdg + 6dgts)
1)
Additional 50.00nF range accuracy is not specified
2)
Accuracies with film capacitor or better
3)
Specified with battery voltage above 2.8V (approx. Half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage
of approx. 2.4V
100 mW
1 W
10 W
100 W
1 KW
10 KW
100 pF
1 nF
10 nF
100 nF
1 m
F
-8-
DCA Current (Clamp-on)
Range
Resolution
1) 2)
Accuracy
400.0 A
0A ~ 50.0A
50.0A ~ 200.0A
200.0A ~ 300.0A
300.0A ~ 400.0A
±(1.5%rdg + 5dgts)
±(2.5%rdg + 5dgts)
1)
Induced error from adjacent current-carrying conductor :
2)
Relative Zero
mode is applied to offset the non-zero residual
readings, if any
r
±(1.0%rdg + 4dgts)
±(2.0%rdg + 5dgts)
ACA Current (Clamp-on)
Range
400.0 A
40Hz ~ 60Hz @ 0 ~ 50A
1)
Induced error from adjacent current-carrying conductor :
Crest Factor :
(Model KM 062 only)
60Hz ~ 400Hz @ 0 ~ 50A
40Hz ~ 60Hz @ 50A ~ 200A
60Hz ~ 200Hz @ 50A ~ 200A
40Hz ~ 60Hz @ 200A ~ 300A
40Hz ~ 60Hz @ 300A ~ 400A
1)
Accuracy
±(1.5%rdg + 5dgts)
±(2.0%rdg + 5dgts)
±(1.0%rdg + 6dgts)
±(1.5%rdg + 5dgts)
±(2.0%rdg + 5dgts)
±(2.5%rdg + 5dgts)
100 mA
100 mA
100 mA
100 mA