La Gard 3000 Installation Instructions Manual - page 12
(P/N)762.128RevBEN05/10•©copyright2009-2010
Kaba Mas LLC
page10
Standard method
The8130EntryDevicecomeswithabackplatewithkeyholeslotsforeaseofmounting(Figure10).
1.Locate,drillandtapholestomounttheEntryDevicetotheoutsideofthesafedoorusingtheinstallationtemplateprovided.
2.Installthetwo#8-32shoulderscrews(US)orthetwoM4-0.7shoulderscrews(Metric)onthefrontofthesafedoortomountthe
EntryDevicetothedoor(Figure11).
3.FeedtheEntryDevicecablethroughthespindlecableholefromthefrontofthesafedoor(Figure12).
4.PositionthekeyholeslottedholesonthebackplateoftheEntryDeviceoverthemountingscrewsandthenslidetheEntryDevice
downontothemountingscrews.
5.Removetheadhesivestripfromthebackofthekeypadandcarefullyalignbeforeadheringtothehousing.Refertolockinstallation
instructionswhichareavailableatwww.kaba-mas.com.
8130 alternate method (tamper evident for vds approval)
The8130EntryDevicecomeswiththemylarportionofthekeypadunattached(Figure13).
1.Locate,drillandtapholestomounttheEntryDevicetotheoutsideofthesafedoorusingthe
installationtemplateprovided.
2.FeedtheEntryDevicecablethroughthespindle/cableholefromthefrontofthesafedoor.
3.InstallthetwoM4-0.7PhillipsscrewsthroughthefrontofthehousingtomounttheEntryDeviceto
thedoor(Figure13).
WARNING: 8130 Before completing the next step, you should ensure that the jumper switches for
time delay/open window are set as desired.
4.Removetheadhesivestripfromthebackofthekeypadandcarefullyalignbeforeadheringto
thehousing.
InordertouseeithertheDeadboltorSpringboltlocks,withEntries3000,3710,3715,and8130a
methodofretractingtheboltwillberequired.KnobAssembly(p/n2666)isrecommended.
Figure10
Figure11
Figure12
Figure13
8130 ENTRY DEVICE