La Gard 8130 Installation Instructions - page 2
(P/N)738.098 Rev A • 04/09
© copyright 2009
Kaba Mas LLC
page 2 of 5
DESIGN PARAMETERS FOR SWING BOLT LOCKS
1. Bolt dimensions (nominal): .309 inches x .900 inches/7.8 x 22.8mm
2. Bolt movement (nominal): .465 inches/11.8mm
3. Bolt extension: .465 inches/11.8mm
4. Maximum load movable by the bolt: None
Note: LA GARD swing bolt locks will not open if force is applied to the end or side of the bolt.
5. Maximum load against bolt when thrown (all directions): 1kN (224.8 lbs.)
6. The lock can be fi tted to safes or vault doors of any material.
Note: As is the case with all mechanical and electronic locking devices, the container and boltworks must be designed to protect
the lock.
SAFEGUARDS FOR MOUNTING
1. Once an electronic lock has been mounted, no more welding can be done on the safe.
2. Keep metal dust, fi lings, etc. away from the lock.
3. Never remove lock cover on a Dead Bolt, Spring Bolt or Swing Bolt lock as this voids warranty policy.
4. Never oil, grease, lubricate or paint the lock.
5. Keep cables away from sharp edges and moving parts.
6. Never carry keypads or locks by the cable.
7. Use 9-Volt ALKALINE batteries only. The use of a high quality, name brand battery (Energizer® or Duracell®) is recommended.
BASIC TOOLS AND MATERIALS REQUIRED:
• Medium Phillips head screwdriver (#2) (recommend magnetized tip)
• Torque screwdriver
• Small fl at fi le or deburring stone
• Tape measure or ruler
• ESD wrist band
For dead bolt, spring bolt, or redundant mechanical installation:
• Fine pitch hacksaw (32 teeth/inch)
• Small vise grip (Recommended)
WARNING: LA GARD locks are protected from 25,000 V Electrostatic Discharge (ESD) damage when correctly installed. Follow
these precautions to avoid ESD damage when installing the lock:
• Handle the keypad assembly by the outer edge only.
• Use an ESD wrist band grounded to the lock or container during installation.
PREPARATION FOR NEW INSTALLATION: (IF REQUIRED)
1. Use the template provided to establish the exact locations (relative to the spindle hole) of the mounting holes for the Entry Device
and the lock assembly. Be sure to consider the cable length from the entry device to the lock.
2. The spindle hole diameter can be a minimum of .406
" (10.3mm) to a maximum of .438" (11.1mm). The .406" (10.3mm) diameter is
recommended. Spindle hole must be deburred.
3. The Entry Device mounting screws require drilled and tapped holes to 3/8
" (9.5mm) depth if possible (minimum 1/4" or
6.4mm depth required.) Drill either the two horizontal mounting holes or the two vertical holes.
4. When mounting the lock unit (i.e., integrating it in a boltwork), make sure that the lock bolt has clearance to freely move to its end
positions and that the shifting force works only in the axial direction (direction of movement). Lateral forces should not be exerted on
the
lock.
5. If other parts of the boltwork are to be connected to the lock unit (e.g., for activating a blocking device), corresponding adapters can
be
fi xed with screws (#10-32 or M4) to the front of the lock bolt (tightening torque for 15mm screwing depth: 200Ncm maximum).