La Spaziale S1 Mini Vivaldi II User Manual - S1 Mini Vivaldi II
S1 Mini Vivaldi II
Owner’s Manual
Page 13
maximum temperature of 97°C (20) is reached, the selection restarts from the
minimum temperature of 91°C (14) (cyclic mode).
3. Once you choose the desired temperature, in order to lock in this value, press
the
ON/OFF
(27) button, the machine will then go back to its normal functioning.
The value of the operating temperature of the machine is easily changed in order to
improve the final result in the cup dep
ending on the coffee blend used and the user’s
personal preference.
4.11.2 Offset Temperature Adjustment
What Does Temperature Offset Do? / How Do I Use it?
The Vivaldi group design exhibits a temperature drop between where the group boiler
temperature probe is located and where the hot water exits the group. Consequently,
the temperature setting shown by the temperature lamps on the front panel may differ
from the water temperature at the group. Ideally, most users would prefer that the
temperature indicated by the temperate lamps exactly matches the water temperature
exiting the group. LaSpaziale has partially accounted for this in its basic design.
However, there are too many machine to machine electrical and mechanical variances
for this to be completely effective. That’s where the temperature offset comes in. The
programmable temperature offset allows a user with accurate group temperature
measuring equipment to enter an offs
et in the range of ±8˚C (for extended offset option
or 0 to -
8˚C for standard offset option) in order to allow their machines temperature
lamps to exactly match the water temperature exiting the group.
Those purchasing new machines from Chris Coffee Service have had the temperature
offset professionally programmed used a Scace device. However, for those obtaining
the expanded offset capability via an upgrade, it is recommended that you note the
current offset prior to upgrading and then duplicate that offset using the instructions
below. If you do not know how to tell what your current offset is, you can find out by
entering the temperature offset mode and then following instructions in paragraph
4.11.2.
4.11.2.1 Extended Temperature Offset Adjustment
Start with the machine in Standby mode (ON/STBY blinking green). Press and hold the
BOILER
button for about 10 seconds until the Boiler light and the ON/STBY light start
flashing. You are now in the temperature offset programming mode.
To enter a positive temperature offset between 0˚C and +8˚C push the
Single Cup
button. Each press will change the offset by +1˚C. An offset of 0˚C is designated by all
temperature lamps off. A +8˚C offset is designated by all temperature lamps plus ECON
on (Low Water on Mini VII Mini). If your positive offset is more than you wish, each
press of the
Double Cup
button changes the offset by -
1˚C.
To enter a negative temperature offset between 0˚C and -8˚C mode push the
Double
Cup
button. Each press will change the offset by -
1˚C. An offset of 0˚C is designated