La Spaziale S1 Mini Vivaldi II User Manual - S1 Mini Vivaldi II
S1 Mini Vivaldi II
Owner’s Manual
Page 7
test, contact your Mini VII dealer and discuss the available options. This test
should be done before using your machine. Water over 3 grains of hardness
needs to be softened or else consider using bottle water. Hard water will require
frequent descaling which is not a trivial procedure on this machine. Over time
use of very hard water could result in the need to replace the steam boiler heater
element. Since the VII Mini has a sealed boiler, replacement of the entire boiler is
required. This is not an inexpensive repair. Be forewarned. Use soft water.
4.4 Filling the Water Tank
1) Remove the drip tray (1)
2) Remove the water tank (4) and fill with soft water to ensure against mineral
buildup in your boilers
3) Replace the water tank (4) and the drip tray (1)
4) Insert the plug into the 110V AC socket, the On/STBY light (22) starts
flashing. (Stand-by mode).
5) Press the
ON / OFF
(27) and
Hot Water
(23) buttons simultaneously. During
this stage, the control lights EMPTY and On/STBY (22) blink while the pump
runs
6) Once you see water coming from the group (10), release both buttons. The
unit is now in Standby mode with the On/STBY light blinking. You have now
primed the pump and filled both boilers with water.
Important Tip: The above procedure is only required on the initial use of the
machine or any time when starting up with empty boilers such as after storage,
boiler clean out, shipment, etc. or any time the boilers have previously been
drained. Otherwise, once this procedure is performed once, it is only necessary
to turn the machine on using the
ON / OFF
(27) button. It is NOT required to
perform the above procedure each time the water tank is refilled.