I. INTRODUCTION
A. HOW a LakeAir UNIT WORKS
In business establishments, millions of airborne particles are continually being circu-
lated through the interior environment. A LakeAir unit removes these smoke, dust
dirt, and pollen particles with an electrostatic process that works this way:
1. The circulating fan draws dirt laden air
through the PREFILTER SCREEN which
collects large lint particles.
2. Then the IONIZING SECTION, with its
many fine ion wires, charges the airborne
particles. As the charged particles move
along the collecting section, they are col-
lected on the collector plates and trapped
there (just like a magnet attracts and collects
iron fillings).
3. The optional ACTIVATED CARBON
FILTER removes odors and freshens the air.
4. The cleaned and purified air is now dis-
charged to recirculate through your establish-
ment.
B. SPECIFICATIONS
Input Voltages
Model LA-1400S
Model LA-2000S
120 VAC 60 Hz
6 Amps
Model LA-1402S
120 VAC 60 Hz
6 Amps
Model LA-2002S
230 VAC 50 Hz
3 Amps
230 VAC 50 Hz
3 Amps
Capacity
800-1100 CFM
245-335 m3/minute
1500-2100 CFM
460-610 m3/minute
21.5” X 19” X 17”
21.5” X 19” X 21.5”
Cabinet Dimensions
(H X W X D)
54.5 X 48.25 X 43CM
54.5 X 48.25 X 54.5 CM
70 lbs.
85 lbs.
Approximate Shipping
Weights
30 kg.
38 kg.
ACTIVATED
CARBON
FILTER
ELECTRONIC
CELL
PRE-FILTER
SCREEN
IONIZING WIRE
SECTION
COLLECTING
CELL PLATES
Page 3