Locate Electronic Air Cleaners consistent with existing air
circulation in the room so that the heating and air
conditioning systems are comple-mented by the air
cleaners.
C.
MOUNTING YOUR LakeAir MODEL LA-1400S OR 2000S ELECTRONIC AIR
CLEANER
LakeAir provides a 6’ cord with every air cleaner, but it is the responsibility of the purchaser
to provide
adequate outlet which meets local codes. An approved extension cord may be
used if it meets local and national
codes.
Both the LA-1400S and LA-2000S are designed with 4 mounting holes on the top and the bottom of the unit.
LakeAir provides eye bolts with the units so they may be hung by chains from supporting beams on the ceiling.
If you choose the optional wall mount for the
LA-1400S or LA-2000S, see the instruction sheet included with the Model 10009 Wall Mount. To mount using
the included eye bolts, follow the instructions below. The unit may be hung so the air flow is from the left to
the right, or from the right to the left depending on the needs of the customer.
1.
Choose an area which compliments the rest of
the air flow
in the room before you mount the air
cleaner.
2.
Make sure you have correct lengths of chain, and
that it is
capable of sustaining the weight of the unit.
Standard hardware
item, link chain with a working
load of at least 100 lbs. Also
make sure you have
mounting lag screws or equivalent
fasteners to at-tach the chain to the ceiling beams or studs. In
some instances, it may be necessary to construct a
mounting
frame to properly suspend the unit.
3.
Locate the ceiling studs or beams and attach the
correctly sized chain. Chain length should be such that it will
not allow the LA-1400S or LA-2000S to have a floor to
bottom height which would pose a hazard to room occupants.
LakeAir recommends a minimum height of eight feet from
floor to bottom when chain hung.
Chain
Mount
Optional
Wall
Mount
Air cleaners must be mounted to strong structural
parts of the ceiling with adequate head clearance,
and should be a minimum of 10 feet from air intake
or exit ductwork
B.
PROPER LOCATION OF MODEL LA-1400 OR LA-2000 ELECTRONIC AIR
CLEANER:
*Air cleaner #1 pulls air from heavy con-
tamination area.
*Air cleaners #2 & #3 maintain general
circulation.
*Air cleaner #4 pulls air from above.
*All air cleaners aid in setting up definite
air
circulation pattern.
LA air pattern should aid, not oppose any pre-
existing air flow pattern due to heating air
conditioning, exhaust and inlet vents.