List of faults
Table. 8
5. TECHNICAL DATA AND CHARACTERISTICS
Table. 9 - Key of figures cap. 5
5.1 General view and main components
fig. 18 - General view FL 24 MCS
Code
fault
Fault
Possible cause
Cure
A01
No burner ignition
No gas
Check the regular gas flow to the
boiler and that the air has been elimi-
nated from the pipes
Ignition/detection electrode fault
Check the wiring of the electrode and
that it is correctly positioned and free
of any deposits
Faulty gas valve
Check the gas valve and replace it if
necessary
Gas valve wiring disconnected
Check the wiring
Ignition power too low
Adjust the ignition power
A02
Flame present signal with
burner off
Electrode fault
Check the ionisation electrode wiring
Card fault
Check the card
A03
Overtemperature protec-
tion activation
Heating sensor damaged
Check the correct positioning and
operation of the heating sensor
No water circulation in the system Check the circulating pump
Air in the system
Vent the system
F04
Card parameter fault
Wrong card parameter setting
Check the card parameter and modify
it if necessary
F05
Card parameter fault
Wrong card parameter setting
Check the card parameter and modify
it if necessary
Fan fault
Wiring disconnected
Check the wiring
Defective fan
Check the fan
Card fault
Check the card
A06
No flame after the ignition
phase
Low pressure in the gas system
Check the gas pressure
Burner minimum pressure setting Check the pressures
F07
Card parameter fault
Wrong card parameter setting
Check the card parameter and modify
it if necessary
A09
Gas valve fault
Wiring disconnected
Check the wiring
Faulty gas valve
Check the gas valve and replace it if
necessary
F10
Delivery sensor 1 fault
Sensor damaged
Check the wiring or replace the sen-
sor
Wiring shorted
Wiring disconnected
F11
DHW sensor fault
Sensor damaged
Check the wiring or replace the sen-
sor
Wiring shorted
Wiring disconnected
F14
Delivery sensor 2 fault
Sensor damaged
Check the wiring or replace the sen-
sor
Wiring shorted
Wiring disconnected
A16
Gas valve fault
Wiring disconnected
Check the wiring
Faulty gas valve
Check the gas valve and replace it if
necessary
F20
Combustion control fault
Fan fault
Check the fan and fan wiring
Faulty baffle
Check the baffle and replace it if nec-
essary
Flue not correctly sized or
obstructed
Check the flue
A21
Poor combustion fault
Fault F20 generated 6 times in the
last 10 minutes
See fault F20
A23
Card parameter fault
Wrong card parameter setting
Check the card parameter and modify
it if necessary
A24
Card parameter fault
Wrong card parameter setting
Check the card parameter and modify
it if necessary
F34
Supply voltage under 180V. Electric mains trouble
Check the electrical system
F35
Faulty mains frequency
Electric mains trouble
Check the electrical system
F37
Incorrect system water
pressure
Pressure too low
Fill the system
Water pressure switch damaged
or not connected
Check the sensor
F39
External probe fault
Probe damaged or wiring shorted
Check the wiring or replace the sen-
sor
Probe disconnected after activat-
ing the sliding temperature
Reconnect the external sensor or dis-
able the sliding temperature
A41
Sensor positioning
Delivery sensor or DHW sensor
detached from the pipe
Check the correct positioning and
operation of the sensors
F42
Heating sensor fault
Sensor damaged
Replace the sensor
F43
Exchanger protection trips.
No H
2
O system circulation
Check the circulating pump
Air in the system
Vent the system
F50
Gas valve fault
Modulating Operator wiring dis-
connected
Check the wiring
Faulty gas valve
Check the gas valve and replace it if
necessary
A51
Poor combustion fault
Inlet/exhaust flue obstruction
Check the flue
5 Sealed chamber
38 Flowswitch
7 Gas inlet
39 Water flow limiter
8 Domestic hot water outlet
42 DHW temperature sensor
9 Cold water inlet
44 Gas valve
10 System delivery
56 Expansion tank
11 System return
72 Room thermostat (not supplied)
14 Safety valve
74 System filling cock
16 Fan
81 Ignition and detection electrode
19 Combustion chamber
95 Diverter valve
22 Burner
114 Water pressure switch
27 Copper exchanger for heating and hot water
138 External probe (not supplied)
28 Fume manifold
139 Room unit (not supplied)
29 Fume outlet manifold
187 Fume baffle
32 Heating circulating pump
194 DHW exchanger
36 Automatic air vent
241 Automatic bypass
37 Cold water inlet filter
278 Double sensor (Safety + Heating)
44
32
114
36
14
19
27
28
56
29
5
16
81
95
278
42
38
37
10
8
7
9
11
194
39
74
187
22