Lansinoh 2in1 ELECTRIC BREAST PUMP Instructions For Use Manual - page 7
3
15
15
AC adapter connector socket
16
AC Adapter
03. Lansinoh
®
2in1 Electric Breast Pump Parts
Item∙/∙Item∙Number
a
Lansinoh 2in1 Electric Breast Pump
Tubing #53403
a1
Silicone Tubes 300 mm (2)
a2
Silicone Tube 600 mm
a3
Tubing Y Connector #53405
a4
Tubing Strap #50417
a5
Pump Connector #53453
b
Breastmilk Expression Set Includes:
b1
∙ ComfortFitTM∙Breast∙Cushion∙(2)∙
#50408
b2
Breast Cushion Body (2) #53454
b3
Diaphragm (2) #53402
b4
Diaphragm Cap (2) #53410
b5
White Valve (2 + 2 extra) #53401
b6
160ml Container (2) #53451
c
Container Ring (2) and Disk (2) #53450
d
AC Adapter/power cord
e
Bottle Holder (2) #53452
b6
b5
b2
b1
b
c
e
d
a
b3
b4
a3
a1
a2
a4
a5
Two∙extra∙white∙valves∙are∙included.∙Larger∙size∙cushions∙are∙separately∙available∙for∙sale.∙
To order replacement part or larger size breast cushions please call +(0)113 205 4201 or
visit∙www.lansinoh.co.uk∙for∙details∙in∙the∙UK.∙You∙can∙also∙contact∙your∙country∙distributor.
Before Each Use…
• Always wash hands thoroughly with soap and water before handling the Breastmilk
Expression∙Set,∙the∙pump∙body,∙or∙other∙attachments.
•∙ Disassemble∙the∙Breastmilk∙Expression∙Set∙to∙clean.∙Set∙aside∙the∙tubing∙as∙it∙does∙not∙
need∙to∙be∙washed∙or∙sterilised.
• Do not operate the pump if liquid or moisture is visible in the tubing, but thoroughly dry it
first∙before∙use∙if∙there∙are∙any∙signs∙of∙moisture.
04. Cleaning Instructions
Unless∙otherwise∙instructed∙by∙your∙healthcare∙provider,∙follow∙these∙sterilisation∙and∙
cleaning∙instructions.
Sterilisation
1.∙ Prior∙to∙using∙the∙set∙for∙the∙first∙time,∙disassemble∙and∙boil∙for∙10∙minutes∙all∙parts∙of∙
the∙Breastmilk∙Expression∙Set∙that∙come∙into∙contact∙with∙breastmilk.∙The∙Set∙includes∙
all∙parts∙except∙for∙the∙pump∙base,∙plug,∙tubing∙and∙tubing∙connector.
•
Note: Ensure you use enough water to keep parts afloat while boiling.
•
Note: Do not boil the tubing and tubing connector.
2.∙ Remove∙all∙parts∙from∙water∙immediately∙after∙boiling.
3.∙ Completely∙air∙dry∙before∙assembly∙and∙next∙use.
•
Note: Partially dried parts may affect operation of the pump.
Please∙ensure∙parts∙are∙completely∙dry∙before∙use.
Cleaning
•∙∙ Set∙aside∙the∙tubing∙and∙tubing∙connector.∙These∙items∙do∙not∙need∙to∙be∙washed∙or∙
sterilised because the diaphragm prevents them from coming into contact with the
breastmilk.
• The breast cushion and containers may be cleaned in the upper compartment of your
dishwasher∙or∙hand∙washed∙with∙dish∙soap∙in∙hot∙water.∙For∙best∙results,∙we∙recommend∙
using a baby bottle brush to clean the container and a teat brush to clean the insides of
the∙breast∙cushion.∙DO∙NOT∙use∙solvents∙or∙abrasives.
•∙∙ Rinse∙with∙hot,∙clean∙water.
• All other parts of the Breastmilk Expression Set should be
hand∙washed∙to∙prevent∙loss∙and∙extend∙their∙usefulness.
• To clean your breast pump, wipe the base with a damp cloth,
using∙only∙water∙or∙mild∙soap.
•
Do not wash or sterilise the tubing or tubing connector.
•∙∙ Note:∙For∙best∙results,∙make∙sure∙the∙diaphragms∙are∙completely∙dry∙before∙use.
•∙∙ Note:∙Before∙using∙the∙Breastmilk∙Expression∙Set,∙visually∙inspect∙the∙individual∙
components for cracks, chips, tears, discoloration or deterioration, as this may affect the
functionality∙of∙the∙Breastmilk∙Expression∙Set.
Please∙visit∙www.lansinoh.co.uk∙or∙call∙+44∙(0)∙113∙205∙4201∙in∙the∙UK∙or∙contact∙your∙
country∙distributor∙for∙further∙guidance∙and∙replacement∙parts.
05. Assembling the Breastmilk Expression Set
Your Breastmilk Expression Set comes preassembled in Lansinoh
®
∙product∙packaging.∙Clean∙
Breastmilk Expression Set parts (except tubing and tubing connector) as described in the
“Cleaning∙Instructions”∙section.∙Once∙all∙parts∙are∙clean∙and∙completely∙dry,∙assemble∙the∙
expression set as follows:
f
Diaphragm Cap
g
Diaphragm
h
∙ ComfortFit™∙Breast∙
Cushions
i
Breast Cushion Body
j
White Valve
k
160ml Breastmilk
Collection Container
1.∙∙ Place∙purple∙diaphragm∙on∙top∙of∙breast∙cushion∙body.∙Then∙place∙and∙twist∙the∙
diaphragm∙cap∙onto∙breast∙cushion∙body∙enclosing∙the∙purple∙diaphragm.
2.∙∙ Push∙ComfortFit™∙breast∙cushion∙into∙breast∙cushion∙body.
3.∙∙ Gently∙secure∙white∙valve∙into∙the∙bottom∙of∙breast∙cushion∙body.
Note: Use caution when handling and cleaning the small white valve.
4.∙∙ Screw∙collection∙container∙onto∙breast∙cushion∙body.
5.∙∙ Insert∙tubing∙into∙back∙of∙diaphragm∙cap;∙ensure∙tight∙fit.
6.∙∙ Insert∙tubing∙connector∙between∙the∙sets.∙Place∙tubing∙input∙into∙the∙pump.
06. Pumping Tips
The∙most∙important∙part∙of∙successful∙pumping∙is∙the∙ability∙to∙trigger∙the∙let-down∙reflex.∙
This∙is∙when∙your∙milk∙begins∙to∙flow∙freely.∙Warm∙wet∙compresses∙applied∙to∙the∙breasts∙
and gentle, circular massaging of the breasts prior to and/or during a pumping session
can∙help∙encourage∙this∙natural∙reflex.∙Thinking∙of∙or∙looking∙at∙your∙baby,∙or∙a∙photo∙of∙
your∙baby∙if∙you∙are∙apart,∙can∙also∙be∙helpful.∙You∙also∙may∙wish∙to∙try∙the∙Lansinoh
®
Therapearl
®
∙3in1∙Breast∙Therapy∙which∙can∙help∙with∙your∙milk∙let-down.
Some∙mums∙can∙achieve∙more∙than∙one∙let-down∙during∙a∙pumping∙session.∙You∙may∙be∙