Lasermate LM-5.5 Operator's Manual - page 18
18
LM-5.5 Operator Manual
Issue 5 January 2012
LM-5.5 Operator Manual
9.
DOUBLE DOCUMENT CaLIBraTION
Each time the machine is run, it will automatically calibrate the first form to measure its
size and thickness. Thereafter, if two forms are fed at the same time, they will be ejected
through the slot below fold plate 2 before reaching the sealing rollers.
If the paper size or weight is changed without switching off, it is advisable to use the cali-
bration button to calibrate again, as shown below.
3. The machine is now ready for use and need not be calibrated again unless the size or
thickness of the form used is changed. If a double document subsequently occurs, it will be
ejected in the same manner, folded but unsealed. Note: if the document does not feed, and
the fault ‘FLt14’ appears, the doubles sensor is dirty or defective. Until this is remedied, only
Handfeed mode can be used (see below).
10.
handfeed
If required the machine can operate in manual mode, allowing, for example a single or small
number of documents to be processed without setting up the rest of the machine. This func-
tion may also be used for sealing diverted forms.
IMPOrTaNT! Do not attempt to handfeed forms if the machine is running.
1. Ensure that the hopper tray is loaded (see section 8.1).
2. Press the calibration button
on the control panel. A single folded
document will be ejected below fold
plate 2. Remove it and check that it
consists of only one sheet. If OK, it
can be sealed using Handfeed (see
section 10 below).
Ejected document slot
1. Pre-fold the document by hand to the re-
quired fold lengths (see section 8.2.4 for fold
options), or remove the diverted form from
the slot below fold plate 2.
2. With the machine switched
on but not running, insert the
folded document, with crease
forwards into the slot in front of
fold plate 1. Ensure it is fully
inserted. The message 'hFEEd'
will appear on the display. Press
the Run button to feed the
document.
3. Repeat as often as required.