SuggeSted cauSe and remedy
1. Ensure emergency stop button is not depressed and
that power cord is plugged into power outlet.
2. Forms improperly loaded - ensure leading edges are
firmly against chassis bridge and that the tray is
depressed (see section 8.1).
3. Ensure side guides are properly adjusted (see sec-
tion 8.1).
4. Paper type has been changed - recalibrate machine
(see section 9).
5. Fold plates not set - see section 8.2.
6. Dirty fold rollers - clean (see section 11)
7. Plate is set too deep for form length - reset the plate
(see section 8.2).
8. Calibration or diverter fault - recalibrate first (see
section 9) and if this fails, contact the Service De-
partment.
9. i) Forms loaded wrong way up - turn over.
ii) Defective cohesive - check paper is within date
and test a sample using handfeed (see sec-
tion 10).
iii) Defective seal rollers - contact the Service
Department.
10. Receiving tray full or not sufficiently extended.
problem
1. Machine will not run.
2. Forms not feeding, although ma-
chine is running.
3. Forms feeding skewed.
4. Double documents occurring fre-
quently.
5. Jam occurring in folder when ma-
chine is first run.
6. Forms keep stopping in folder
area.
7. Form doesn’t exit first fold plate.
8. Form exits through slot in front
of fold plate 1 but is not a double
document.
9. Forms not sealing, or failing to
seal completely.
10. ‘Flt8’ error message occurring.
13. OPEraTOr’S TrOUBLESHOOTING GUIDE
If problems occur, refer to the guide shown below before contacting the Service De-
partment.