LDA MPS-8Z S02 User Manual - page 12
3.2.7 ALL/CLEAR
The "ALL/CLEAR" button is located in the right upper part of the keyboard. It allows to
select every zone memory available. When one or more zone memories are selected, all of them
can be deselected by pushing the button.
3.2.8 BUS TERMINATOR
The terminator selector "BUS END" is located in the upper part of the base of the
equipment. It allows to activate/deactivate the bus terminator. This control must be active when the
equipment is in the last position in the ACSI bus.
3.2.9 EXPANSION KEYBOARD IDENTIFIER
The keyboard selector is only available on expansion keyboards attached to the MPS 8Z.
"ID" is located in the middle of the base of the equipment. It allows to choose the position of the
keyboard in the expansion keyboard of the set. Each keyboard must have a unique identifier. In a
system where memory keys have not been configured, the zone of each expansion keyboard is
determined by the selected identifier. Then we have:
•
ID 1: Zones 9-16
•
ID 2: Zones 17-24
•
ID 3: Zones 25-32
•
ID 4: Zones 33-40
•
ID 5: Zones 41-48
•
ID 6: Zones 49-56
•
ID 7: Zones 57-64
•
ID 8: Position not allowed
•
ID 9: Position not allowed
•
ID 0: Position not allowed
3.2.10 POWER SUPPLY SELECTOR
The equipment has a selector that allows to choose the energy source between local or
provided through the ACSI bus. When the selector is in 5V position, the equipment will be locally
supplied by the external charger provided with the equipment. In this mode, in the event of a
supply problem through the charger, the equipment will be automatically supplied from the ACSI
bus. If the selector is in the 24V position, the MPS 8Z will be supplied exclusively from the ACSI
bus.
LDA Audio Tech - Severo Ochoa Nº 31- 29590 MÁLAGA, ESPAÑA. Tlf: +34 952028805
5