Setup
Setup your RVS-8 via the front panel buttons and LDC display. Setup data is stored in non-
volatile EEPROM, and remains intact when power is removed.
Hysteresis
The hysteresis level is the amount of signal-to-noise ratio improvement needed over the currently
voted site for a new site to be voted. Press the
Menu
button until the present hysteresis value is
displayed. Press the
Data
button to select the desired value. Available values are 0 - 8. You
should adjust this to a higher value if you experience excessive switching between receivers. A
higher value requires more improvement in the signal-to-noise ratio for switching to occur. The
normal value should be 3 or 4.
Disabled Channels
Press the
Menu
button until the presently disabled channels are displayed. To disable or enable a
channel, press the
Selection
button to scroll across to the desired channel. Press the
Data
button
to toggle between enabled and disabled. The channel is disabled when the channel number
appears in the Disabled Channels display.
This display also reflects channels disabled via hardware connected to J3. Channels disabled in
software via this menu cannot be enabled via hardware, and vice versa.
Be sure not to disable all channels. This would effectively turn off the repeater as no inputs would
be passed through.