ESUVIUS OWNERS MANUAL
DRAFT
COPY
Set the
temperature of the
brew boiler (also
accessible from
main menu)
How many minutes after
machine enters economy
mode, before it switches
to standby(if not used).
0
to disable
Allows for the drop in temperature
of water as it passes from the brew
boiler to the coffee. E.g. Brew
Boiler water at 107 c, but 94 c is
displayed
PID Values for Brew Boiler. We do not recommend you
change these unless the brew temperature overshoots,
or is constantly higher than set on your machine. If this
is the case, try kD values of 8.0, 8.5 and 9.0 Choose the
lowest of the values that gives satisfactory results.
Temperature range around set
point where PID operates. We
want a larger range for the brew
boiler. You machine may be set to
7C, we recommend you change
this to 5C
This value is the number of seconds the machine will wait before
1. Closing the mains water solenoid, preventing flooding if a fault develops on
a plumbed machine
2. Showing the red fill tank screen, when the water level is low
3. The length of time the pump will run when auto-filling the steam boiler
If you often walk away from the machine and miss the red low water warning
on the display, you can reduce this value to 100 seconds.