Magenta MultiView II DVI-Rx-1K Quick Start Manual - page 2
© 2014 tvONE, 2791 Circleport Drive, Erlanger KY 41018 USA
Americas: 859-282-7303, EMEA: +44 (0)1843 873322, email:
tech.usa@tvone.com
www.tvone.com
Document # CSG-MULTIVIEW-RX Rev-08 (09-Mar-2015)
Page 2 of 3
Manual EQ Adjustment: To manually adjust the EQ setting, simply use the UP or DOWN buttons. The EQ/SKEW indicators 1-8 will
show the current setting as 1-8 (0-100%) of the available EQ adjustment range.
(starting in normal-mode)
Press & hold the UP or DOWN button until the SKEW/RGB indicator turns on (VIOLET). Release the UP or DOWN button.
Press the UP or DOWN buttons repeatedly to adjust the EQ setting, either one step at a time or hold for auto-repeat.
To exit EQ-ADJUST mode, leave the buttons untouched for 10 seconds, or press the CFG button once.
Note:
For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the tvONE website.
Manual Skew Adjustment: To manually adjust the Skew setting, simply use the UP or DOWN
buttons after getting into “Skew-adjust”
mode. The EQ/SKEW indicators 1-8 will show the current setting as 1-8 (0-100%) of the available Skew adjustment range for each
color.
(starting in normal-mode)
RED skew adjust: Press & hold the SKEW/SEL button until the SKEW/RGB indicator turns on RED. Release SKEW button.
Press the UP or DOWN button repeatedly to adjust the RED skew value.
GREEN skew adjust: Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn GREEN.
Press the UP or DOWN button repeatedly to adjust the GREEN value.
BLUE skew adjust: Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn BLUE.
Press the UP or DOWN button to adjust the BLUE value.
Pressing the SKEW/SEL button again will return you to step-2, allowing adjustment of the RED skew again.
To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the CFG button.
Note:
For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the tvONE website.
Re-enabling the auto-EQ/Skew feature: From normal mode, press both the UP and DOWN buttons simultaneously. Hold both buttons
down for 1 second or more.
The auto-EQ/Skew feature will be enabled and the receiver will immediately enter EQ-hunt mode. Within
seconds, valid EQ and Skew settings will be found. You MUST manually adjust for the best picture.
Changing Internal Settings:
In configuration-mode (CFG indicator = on), the CFG and SKEW/SEL buttons, plus the LED indicators
(1-8) will allow you to change internal configuration settings. The changes are effective immediately and are saved in non-volatile
memory.
To enter configuration-mode: Press and hold the CFG button until the CFG indicator is ON. Once in this mode, LEDs 1-8
will display the current settings as described in the tables below.
To exit configuration-mode: Leave the buttons untouched for 10 seconds or press the CFG button again. The CFG indicator
will turn off (normal-mode).