Magenta Research MultiView II AK1200DP Installation And User Manual - Chapter 4
Installation
MultiView™ II AK600DP/AK1200DP
Installation and User Guide
6
Chapter 4
Installation
This section describes the following installation topics:
Data mode configuration
Prerequisites to installation
Installation procedure
Post-installation adjustments
Post-installation configuration settings
This equipment is not intended for, nor does it support, distribution through an Ethernet network.
Do not connect these devices to any sort of networking or telecommunications equipment!
Do not connect DC power until instructed to do so.
4.1
Option-Module Configuration
If you are installing a MVII-AK600(1200)DP-
SAP
version receiver (this is equipped with the SAP hardware
option module), then the following information will be important to review BEFORE installing the receiver:
The
MVII-AK600(1200)DP-SAP
version offers pollable RS232 duplex serial in addition to stereo audio. The
serial interface is 3-wire (TX, RX, GND) and does not support full modem signals. The factory-default serial
baud rate is 9600 baud, but this is a user-
configurable option using “SAP-II” serial commands. Simplex modes
are supported without jumpers or other changes, by simply using the TX signal only. The SAP-module
capability of polling and interacting with specific receivers requires that each receiver have a unique address
setting. Please refer to Appendix-C for (SAP) module configuration information, and Appendix-D for SAP-
address settings. Setting this address involves opening your unit and setting DIP switches inside.
4.2
Prerequisites
Depending on the specific installation requirements, some common tools (screwdrivers, nut-drivers) and related
hardware (mounting screws) might be required. These are not provided with Magenta products.
The following items might be necessary, which are available from Magenta Research:
Audio cable: Phoenix 4-pin to RCA.
Video cable: HD15 connectors, or one of several BNC/RCA/S-Video breakout cables.
Serial cable: Phoenix 4-pin to DB9, or one of several DB9-M/F, M/M or F/F extension cables.
Note:
You will need appropriate twisted-pair cable as previously described, to connect the MVII-
AK600(1200)DP to other MultiView