Magmaweld MONOSTICK 200 PFC User Manual - page 8
Manual Metal Arc Welding
Direct Current
Descending Characteristics
Line Input-1 Phase Alternating Current
Appropriate To Operate In Dangerous Work Area
X
:Duty Cycle*
U
:Open Circuit Voltage
U
:Line Voltage and Frequency
U
:Rated Welding Voltage
I
:Input Current
I
:Rated Welding Current
IP23S
:Protection Class
S
:Input Power
0
1
2
1
2
1
Single Phase Static Frequency Converter
Transformer Rectifier
7
MONOSTICK 200i PFC
1.5 ACCESORRIES
STANDARD ACCESORRIES
PIECE
PRODUCT CODE
K301000203
K301100203
1
1
Electrode Holder and Cable (16mm² - 3m)
Earth Clamp and Cable (16mm² - 3m)
VALUE
UNIT
TECHNICAL SPECIFICATIONS
Line Voltage (Single Phase)
Input Power
Input Current
Open Circuit Voltage
Welding Current Range
Rated Welding Current
Protection Class
(%
)
Rated
(%
)
(%
)
( x x )
20
20
Power Factor
20
Fuse
Cooling Method
Dimensions L W H
Weight
Standards and Approvals
V
kVA
A
V
A
A
A
mm
kg
DC
DC
DC
2 0
3
6,6
29
85
30 - 200
200
32 - Delayed
IP23S
Air
450x160x312
CE, EN60974-1, EN60974-10
0,99
9,1
30A / 21.2V
200A / 28V
~
MONOSTICK 200i PFC
U =85V
0
U =230V
1
I
=29A
1max
I =13A
1eff
20
%
60
%
100
%
20
0A
115
A
90
A
28V
29A
6.6kVA
24.6V
14.5A
3.3kVA
23.6V
10.6A
2.4kVA
EN 60974-1 / EN 60974-10
TECHNICAL INFORMATION
1.3 DATA PLATE
*Duty Cycle
1
2
Temperature ( C)
°
Time (min.)
6 min.
6 min.
6 min.
4 min.
4 min.
4 min.
Duty cycle defines the percentage of welding time out of a period of 10 minutes at a given current and ambient
temperature (standard is 40°C). For example, a welder with 60% duty cycle must be rested (2) for 4 minutes,
after 6 minutes of continuous welding (1).