Magner 35-2003 Series Operator's Manual - page 10
To set a batch:
- Touch the desired number using the numeric key.
- A 3-digit display indicates the preset batch number.
- The machine is now ready to count in the preset batch mode.
To clear the current preset batch number and batch setting:
- Press
0
key until the 3-digit display indicates "0".
- Press the desired number again.
START
STOP
Start/Stop Key
- This key can be activated when the manual start mode is on.
- The machine starts counting when this key is pressed.
- The machine stops counting when this key is pressed during the counting.
(The note count for the batch may be inaccurate.)
0
CLR
Clear Key
Press the key to clear the count figures on the display and reset errors.
+
ACCM
Accumulation
Key
This function keeps a running total of the number of noes counted.
- To start the running total function, press
+
ACCM
key.
"ACCM" appearing on the display indicates this function is on.
IMPORTANT
Any batch that has an error is not counted in total. Any batch
count that is interrupted by an error must be counted again.
To turn off this function, press
+
ACCM
key again. The “ACCM” in the display will
go out. When counting begins again, the display will start from zero.
Density Key
Five different density levels are available.
Currency that is light or dark colored can be counted with fewer errors by
changing the density settings.
LEVEL 1: This is the most sensitive level to catch double notes that have a
very similar level to single notes.
8