VII. Error Codes
When an error occurs, the machine immediately stops and produces an
electric “beep” while the display alternately flashes the error code and count
figure.
The note count for the batch in which the error occurred may be inaccurate.
NOTE
To ensure an accurate count, recount the last batch in the stacker
after correcting the error and pressing
0
CLR
key.
Use tables on the following pages to find the error code, possible causes and
corrective actions.
1. Sensor Error Codes
Error Code
Corrective Action
HJ
Hopper sensor is blocked - Remove the note(s) from
the hopper to restart.
SJ
Stacker sensor is blocked - Remove the note(s) from
the stacker to restart.
JA
Count sensor is detecting note(s) in the machine -
Remove the note(s) to restart.
FEEd
Feed motor is not working.
CSE
Count sensor(both left and right) error - Clean the
sensors to restart.
CSE1
Count sensor(left) error - Clean the left side sensor
to restart.
CSE2
Count sensor(Right) error - Clean the right side
sensor to restart.
2. Counting Error Codes
Error Code
Corrective Action
HF
Half note detected - Press
CH
Chained note detected - Press
dbL
Double note detected - Press
SE
Skewed - Press
SC
Short count when batching. When the notes on the
hopper were not enough to reach the desired
number.
SF
Stacker is full(notes in the stacker reach 200 pieces) -
Remove the notes from the stacker.
13
Magner 35-2003 / 35-3 Series