    Model jm4 magnetostrictive level transmitter hart installation and operating manual software v1.X.

  • Page 2

    2 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 3 read this manual before installing this manual provides information on the jupiter® magnetostrictive transmitter. It is important that all instructions are read carefully and followed in sequence. D...

  • Page 3

    4 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 5 caution sensitive electronic devices do not ship or store near strong electrostatic, electromagnetic, or radioactive fields 1.0 installation caution: ifequipmentisusedinamannernotspecifiedbyman- ufa...

  • Page 4

    6 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 7 1.1.7 remote mount transmitter head for applications with possible clearance or transmitter accessibil- ity issues, the jm4 is available with a remote mount transmitter head. This transmitter head c...

  • Page 5

    8 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 9 4. The upper clamp will need to be open to a large enough diam- eter to be able to mount to the mli as well as the probe. The upper clamp should be positioned just above the 3/4” npt threads. 5. Mou...

  • Page 6

    10 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 11 1.3.3 centering disc all jupiter model jm4 transmitters that come with a stilling well are also provided with a centering disc to prevent the probe from making contact with the stilling well. 1.4 ...

  • Page 7

    12 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 13 4. Connect an earth ground wire to the nearest green ground screw per local electrical code (not shown in illustration). 5. Connect the positive supply wire to the (+) terminal and the negative su...

  • Page 8

    14 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 15 1.5.2.4 entering numeric data using increment/decrement use this method to input the following data into parameters such as damping and failure alarm. Push button keystrokeaction up incrementsthed...

  • Page 9

    16 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 17 the home screen presentation can be customized by viewing or hiding some of these items. See display config under the device setup menu in section 1.6.4 hart menu - model jm4. Figure 1-9 is an exa...

  • Page 10

    18 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 19 1.5.6 modeljm4configurationmenu–devicesetup *onlyavailablewhenmeasurementtype=volume&level **notavailablewhenmeasurementtype=interfaceonly ***onlyavailablewhenmeasurementtype=interfaceonlyorinterf...

  • Page 11

    20 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 21 1.5.6 modeljm4configurationmenu–devicesetup identity basic config volume config i/o config local display config advanced config factory config language: english français deutsch español Русский po...

  • Page 12

    22 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 23 1.5.6 modeljm4configurationmenu–devicesetup identity basic config volume config i/o config local display config advanced config factory config elec temp offset: -60 to +60 º c napvalue: 0 to 59999...

  • Page 13

    24 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 25 1.6.4 hartmenu–modeljm4 note: numbered menu boxes below correspond to numbered tables on section 1.6.5. 1 pv 2 pv analog output 3 pv % output 4 device setup 5 setup wizard 6 diagnostics 7 measured...

  • Page 14

    26 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 27 1 pv 2 pv analog output 3 pv % output 4 device setup 5 setup wizard 6 diagnostics 7 measured values 1 present status 2 event history 3 advanced diagnostics 4 echo curves 5 echo history 6 trend dat...

  • Page 15

    28 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 29 1.6.5 hartmenuitems(contd.) 3 display description 1 enter password 2 tag textthatisassociatedwiththefielddeviceinstallation.Thistextcanbeusedbytheuserin anyway.Arecommendeduseisasauniquelabeltoapl...

  • Page 16

    30 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 31 1.6.5 hartmenuitems(cont.) 8 display description 1 enter password 2 pv is anindexlocationthatindicateswhichfielddevicedynamicvariablehasbeenmappedinto theprimaryvariabledynamicvariable. 3 pv 4 ma ...

  • Page 17

    32 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 33 1.6.5 hartmenuitems(cont.) 10 display description 1 enter password 2 blocking distance distance below the reference point within which level is ignored. (operationisundefinedwhentheliquidleveliswi...

  • Page 18

    34 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 35 1.6.5 hartmenuitems(cont.) 15 display description 1 present status showsthepresentstatus(health)ofthetransmitter. 2 event history thehistoryofthe10mostrecentdiagnosticevents. 3 advanced diagnostic...

  • Page 19

    36 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 37 1.6.5 hartmenuitems(cont.) 22 display description 1 echo graph 2 curve 1 selecttheprimarycurvetodisplay. 3 curve 2 selectthesecondarycurvetodisplay. 4 refresh graph click to refresh echo curve. 5 ...

  • Page 20

    38 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 39 2.0 referenceinformation this section presents an overview of the operation of the jupiter magnetostrictive transmitter, information on troubleshooting common problems, listing of agency approvals...

  • Page 21

    40 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 41 2.3.2 troubleshooting table problem solution blankdisplay ensurelocalkeypad/lcdisproperlyinstalled. Removepowerandreapplypowertotheunit. Check to see if led on module is illuminated. Check voltage...

  • Page 22

    42 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 43 2.3.3 status messages display message briefdescription solution no probe no probe connected to transmitter checkprobeconnectiontotransmitter,consultfactory new probe probememorycontents disagree w...

  • Page 23

    44 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 45 2.4 configurationinformation 2.4.1 volumetric capability selecting measurement type = volume and level allows the model jm4 transmitter to measure volume as the primary mea- sured value. 2.4.1.1 c...

  • Page 24

    46 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 47 2.4.1.2 configurationusingcustomtable if none of the nine vessel types shown can be used, a custom table can be created. A maximum of 30 points can be used to establish the level to volume relatio...

  • Page 25

    48 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 49 2.4 agency approvals these units are in compliance with the emc directive 2004/108/ec, the ped directive 97/23/ec and the atex directive 94/9/ec. Explosion proof us/canada: class i, div 1, group b...

  • Page 26

    50 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 51 2.4.1 agencyspecifications–fm/csaintrinsicallysafeinstallation r "see note 2" 2 jupiter jm4-51xx-xxx + - tb1 j1 current loop c c 2.4.2 agencyspecifications–fm/csaintrinsicallysafefoundationfieldbu...

  • Page 27

    52 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 53 2.5 specifications 2.5.1 functional/physical system design measurement principle magnetostriction-based mechanical response signal input measured variable level,responsesignaltimeofflight span 6in...

  • Page 28

    54 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 55 2.5.4 physicalspecifications-transmitter inches [mm] 10.04 255.1 45° 3.39 86 4.18 106.2 3.77 95.9 3.96 100.7 8.35 212.1 5.09 129.4 transmitter head 16.92 429.7 20.92 531.3 16.92 429.7 directinsert...

  • Page 29

    Ori-xxx jupiter magnetostrictive transmitters 57 56 ori-46.650 jupiter magnetostrictive transmitters 2.5.5 power supply requirements 2.5.5.1 safe operating area 2.5.5.2 terminal voltage operational mode current consumption vmin vmax hart general purpose 4ma 20ma 16.25v 11v 36v 36v intrinsicallysafe ...

  • Page 32

    Ori-46.650 jupiter magnetostrictive transmitters 63 62 ori-xxx jupiter magnetostrictive transmitters (1)electronicmodule digit 5 replacement part 1 031-2856-001 2 031-2856-002 (2)displaymodule digit 5 digit 7 replacement part 1,2 0,1,2 ------------ a,b,c 031-2850-001 (3)wiringpcboard digit 5 replace...

  • Page 33

    64 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 65 magnetostrictive utilizing the wiedemann effect to create a mechanical torsion or twist in a ferromagnetic wire which occurs as a result of the interaction between an elec- trical pulse on the wir...

  • Page 34

    66 ori-46.650 jupiter magnetostrictive transmitters ori-46.650 jupiter magnetostrictive transmitters 67 data sheet: ori-345.0 customer quote reference # phone # contact name e-mail address lower liquid max operating pressure lower liquid specific gravity max operating temperature upper liquid (appli...

  • Page 35

    68 ori-46.650 jupiter magnetostrictive transmitters 2105 oak villa boulevard • baton rouge, louisiana 70815 • 225-906-2343 • toll free 866-55-orion • fax 225-906-2344 • www.Orioninstruments.Com copyright © 2016 magnetrol internaŠonal, incorporated. All rights reserved. Printed in the usa. Magnetrol&...