Magnifico ME10 Use And Maintenance Manual - page 8
15
Use and maintenance manual
14
Choose the convection/steam mixed cooking by tur-
ning the M1 knob to clockwise to position I4.
Then choose the cooking temperature by turning the
M2 knob to the desired temperature.
Set the cooking time by turning the M3 knob. Place
the knob indicator on the I6 symbol to avoid the
timer. When the timer set will be over the oven will
buzz and turn off itself.
Set the fan spped using the button T1.
2. Use instruction (combi-ovens)
2.5 Convection/steam mixed cooking
I 1
I 4
I 5
S 1
S 2
I 7
I 8
M 1
M 2
M 3
I 6
T 1
2.6 Humidity drainig valve
The humidity draining valve has the task of expelling
humidity formed inside the cooking chamber during
the cooking.
Move the butterfly valve stick L1 to the following
positions:
•
P1 left: VALVE CLOSE
•
P2 right: VALVE OPEN
Even with the valve closed, there is no risk of over-
pressures inside cooking compartment as because
over-pressure is controlled by the drain.
During the STEAMING and CONVECTION/STEAM
MIXED cooking it is suggested to keep the butterfly
valve closed (position P1).
The compartment lights swich on automatycally when the oven is turn on and the M3 knob is activated. When the
cooking is done (timer is 0) lights will turn off automatically.
To stop a cooking process turn the M3 knob (Time)
to position “0”.
Turn the M1 knob to OFF position to switch off the
oven.
2.7 Compartment lighting.
2.8 Off and oven swich
off.
M 3
M 1
led 1
2.9 Flame control - gas ovens only
2. Use instruction (combi-ovens)
The flame control uses a special electrode to ensure burner/s work properly.
Should the burner/s accidently go out or malfunction the system signals an error, the corresponding light on the
control panel lights, the gas is shut off and the cooking session is temporarily interrupted so that the operator can
intervene. In order to reset press the lighted button for 1 second. The flame control will automatically perform three
attempts to reset before signaling an error.