Maico EC 140 B Mounting And Operating Instructions

Manual is about: Ceiling fans

Summary of EC 140 B

  • Page 1

    D gb f deckenfächer ceiling fans ventilateurs de plafond ec 30 e ec 90 b ec 40 d ec 140 b montage- und betriebsanleitung mounting and operating instructions instructions de montage et mode d’emploi www. Mai c o.De.

  • Page 6: Ceiling Fans Ec …

    11 ceiling fans ec … table of contents 1. Scope of delivery................................... 11 1.1 ec 30 e and ec 40 d..................... 11 1.2 ec 90 b and ec 140 b................... 11 2. Warning symbols used .......................... 12 2.1 warning symbols ............................ 12 2...

  • Page 7

    12 2. Warning symbols used 2.1 warning symbols danger danger to life. Non-observance can lead to death or serious bodily injuries. Caution danger of injury. Damage to property. Non-observance can lead to minor or more serious bodily injuries. Notice damage to property. Non-observance can lead to dam...

  • Page 8

    13 3.3 product description ceiling fan for air circulation in commercial and working areas. Ec 30 e and ec 40 d run clockwise. Ec 90 b and ec 140 b run anti-clockwise (see direction of rotation arrow sign [s5]). The motor is designed for continuous operation. In the event of thermal overload, an int...

  • Page 9

    14 1 operations only permitted when fitted at a sufficient space from the wall, other ceiling fans or equipment in the vicinity. 1 ec 90 b, ec 140 b: operation only permitted with a minimum gap of 2.3 m between floor and bottom edge of impeller blades. 5.3 non-permitted operation the fan unit should...

  • Page 10

    15 7.2 ec 90 b and ec 140 b installation danger incorrect installation results in a danger of injury from falling unit parts. 1 install impeller blades as shown (fold-out side) and screw down correctly. 1 observe tightening torques. 1 only use impeller blades of the same weight on the impeller blade...

  • Page 11

    16 1 lift up ceiling fan. 1 hang rubber roller of fastening rod [20] in ceiling hook [14]. 1 undertake electrical connection according to section 7.3. 1 slide canopy [17] towards ceiling and lock with setting ring [19]. 7.3 electrical connection danger danger to life from electric shock 1 switch the...

  • Page 12

    17 8.1 ec 30 e, ec 40 d fastening rod 1 disconnect motor connection cables [8] from connecting terminal [7]. 1 slide up motor cover [11]. 1 carefully pull connection cable [8] at bottom out of fastening rod [6]. 1 loosen retaining threaded pin of lock nut [9]. 1 unscrew fastening rod [6] out of moto...

  • Page 13

    18 8.2 ec 90 b, ec 140 b fastening rod 1 disconnect motor connection cables [15] from connecting terminal [16]. 1 carefully pull motor connection cables [15] at bottom out of fastening rod [20]. 1 remove nut [21] and bolt [22] and pull fastening rod off retaining bolt [23.1]. 1 take off canopy [17] ...

  • Page 14

    19 11. Cleaning danger danger to life. Unit is powered up. 1 switch the mains fuse off. 1 if the impeller blades are dirty or not running smoothly (imbalance), clean the unit with a damp cloth. 12. Fault rectification 1 call on the services of a trained electrician any time there is a fault. 1 repai...

  • Page 15

    32 14. Schaltbilder / wiring diagrams schémas de branchement ec 30 e ec 90 b, ec 140 b ec 40 d maico elektroapparate-fabrik gmbh • steinbeisstr. 20 • 78056 villingen-schwenningen • deutschland • service-hotline +49 1805 694 110 • info@maico.De m 1 l n p e n 6 5 w h b k m 1 l n p e n 6 5 w h b k r d ...