Framing And Finishing
Check fireplace to make sure it is lev-
elled and properly positioned.
To mount the appliance:
1. Choose the location.
2. Nailing flanges are supplied with the fireplace (found
on the fireplace hearth). To level the box and secure
it firmly in place, remove the nailing flanges from the
hearth and install at the sides of the fireplace as
shown in Figure 5.
3. Screw through the slotted holes in the drywall strip
and into pre-drilled holes in fireplace side. Measure
from face of fireplace to the face of the drywall strip
to confirm the final depth.
Final Finishing
Noncombustible materials such as brick or tile can be
extended over the edges of the face of the fireplace. Do
not cover the window frame assembly, any vent,
louvre assembly top or louvre assembly bottom. If a
Trim Kit is to be installed, brick and tile will have to be
installed flush with the side of this appliance.
DV360 / DV580
Certified To
ANSI Z21.88-2002/CSA 2.33-M-99
Vented Gas Fireplace Heater
Fig. 5 Adjustable drywall strip (nailing flanges).
C
A
B
Adjustable Drywall Strip
(Nailing Flange)
Screw
Drywall
Position
Depths
A
1/2” / 13mm
B
5/8” / 16mm
C
3/4” / 19mm
FP1023
Adjustable
1/2”, 5/8” &
3/4” Spacing
Gas Inlet and Manifold Pressures
Natural
LP (Propane)
Minimum Inlet Pressure
5.5” w.c.
11.0” w.c.
Maximum Inlet Pressure
14.0” w.c.
14.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Gas Specifications
MAX.
MIN.
GAS
INPUT
INPUT
MODEL
FUEL
CONTROL
B.T.U.H
B.T.U.H.
DV360RN
Natural Gas
Millivolt Hi/Lo
30,000
21,000
DV360RP
Propane
Millivolt Hi/Lo
30,000
21,000
DV360RFN
Natural Gas
Comfort Control
30,000
21,000
DV360RFP
Propane
Comfort Control
30,000
21,000
DV580RN
Natural Gas
Millivolt Hi/Lo
38,000
26,500
DV580RP
Propane
Millivolt Hi/Lo
38,000
27,000
DV580RFN
Natural Gas
Comfort Control
38,000
26,500
DV580RFP
Propane
Comfort Control
38,000
27,000
High Elevations
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
Gas Line Installation
When purging gas line the front glass
must be removed.
The gas pipeline can be brought in through the right
side of the appliance. Knockouts are provided at
convenient locations to allow for the gas pipe installa-
tion and testing of any gas connection.
The gas line connection can be made with properly
tinned 3/8" copper tubing, 1/2" rigid pipe or an approved
flex connector. Since some municipalities have
additional local codes, it is always best to consult your
local authority and the CSA-B149.1 installation codes.
For USA installations consult the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54.