HEATER STAND AND LOCATION
• The heater is primarily for outdoor use only.
Always ensure that adequate fresh air
ventilation is provided.
• Always maintain proper clearance to
combustible materials, i.e. top 2m and sides
2m minimum. Heater must be placed on
level firm ground.
• Never operate heater in an explosive
atmosphere like areas where gasoline or
other flammable liquids or vapors are
stored.
• To protect heater from strong wind, anchor the base securely to the ground with
screws.
GAS REQUIREMENTS
• For use with LP Gas mix only.
•
LP Gas regulator must be a 2, 8kPa regulator that complies with the requirements of
SANS1237
.
• The hose assembly to be used must conform to local standard codes.
• The installation must conform to local codes, or in the absence of codes, with the
standard for storage and handling of liquid petroleum gases. SANS 1539:2012
• A dented, rusted or damaged LP gas cylinder may be hazardous and should be
checked by your cylinder supplier.
• Never use a LP gas cylinder with a damaged valve connection.
• The LP gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
• Never connect an unregulated LP gas cylinder to the heater.