MEGAPLUS GigE Vision Features Manual - page 11
MEGAPLUS
GigE Vision Features Guide (Customer Edition)
4411-0128, Rev. A
07/28/09
7
GreenGain: (R/W) This feature sets/returns the analog gain value for the specified head (or tap
where appropriate). Head and sensor tap are set by previously defined individual
commands. Min: 1, Max: 63
HeadFanState: (R/W) This feature turns the head cooler fan on/off state for a camera with a
fan. On/Off
HeadSensorTargetTECTemp: (Read) This feature returns the temperature (in Celsius) of the
camera head sensor TEC. Min: -20, Max: 60
HeadTECState: (R/W) This feature turns the TEC on or off for the camera head sensor. The
TEC state must be set to Auto if you want to activate a target temperature setting entered
via the HeadSensorTECTargetTemp. Off/On/Auto
HeadTargetTECTemp: (R/W) This feature sets/returns the target temperature (in Celsius) of
the camera head sensor TEC. This target temperature setting will be only used if
HeadSensorTECState has set the TEC state to Auto. Min: -20, Max: 60
HeadTemperature: (Read) This feature returns the temperature (in Celsius) of the camera.
Used for cameras that do not contain a TEC. For cameras containing a TEC, refer to the
TEC-related commands (for example, HeadTECState). Min: -100, Max: 250
HeadsAttached: (Read) This feature queries the camera and returns the number of heads
currently attached to the console (controller). Min: 1, Max: 1
HeadsSupported: (Read) This feature returns the maximum number of heads that this console
can support. Min: 1, Max: 1
MechanicalShutter: (R/W) This feature sets/returns the state of the mechanical shutter.
“0” =
locked closed; “1” = trigger activated; “2” = locked open. Min: 0, Max: 2
NOTE: Mechanical shutters are present in Princeton Instruments’ full frame Camera
Heads, the ES 1602/1603 and ES 3200. The mechanical shutter functions have no
effect on Camera Heads employing interline sensors.
Mode6Interval: (R/W) When operating in triggered Mode 6 (Periodic Interval), which causes
the camera to self-trigger an image repeatedly at a specified time interval (in milliseconds),
this feature is used to set/return the time period between triggers. The typical range is 1/Max
frame rate of the sensor to 5 minutes. Min: 1, Max: 32767
PixelClockFrequency: (Read) Returns the floating point value for the current pixel clock
frequency in MHz for the active camera. Min: 0, Max: 40
RedGain: (R/W) This feature sets/returns the red analog gain value for the camera (or tap
where appropriate). Camera and sensor tap are set by other defined individual features.
Min: 1, Max: 63