Table 3-3 Settings in the System Menu – Continued
memreset
Restores the defaults of the
608MFX. The device is
automatically restarted.
Administrator command
restores the factory settings of
the 608MFX. With the
exception of the ”protected
settings”, the settings made by
the user are reset to the default
values.
setsysc
Sets the syscontact MIB variable.
(To insert a blank in a string, use the
tilde (~) instead of a blank.)
Administrator only
setsysl
Sets the syslocation MIB variable.
(To insert a blank in a string, use the
tilde (~) instead of a blank.)
Administrator only
setsysn
Sets the sysname MIB variable. (To
insert a blank in a string, use the
tilde (~) instead of a blank.)
Administrator only
events
Show | Clear content of the event
log table.
Only the administrator can
delete the event log table.
The event log table contains all
the events that cause traps or
E–mails (when enabled). Other
fault/error events such as
communication errors are also
logged with the SMTP server.
The content of the event log
table is retained even when the
608MFX is turned off.
addlog
This command makes an entry in
the log of the 608MFX.
Administrator only
server
Sets the IP address of the TFTP
server from which the new firmware
for the 608MFX will be
downloaded.
Administrator only
fwname
< filename>
Enters the name of the file on the
TFTP server containing the new
608MFX firmware (max. 32
characters) possibly including
further path information (depending
on the configuration of the TFTP
server).
Administrator only
fwload
Starts the firmware download from
the TFTP server.
Administrator only