NAD T 758 Owner's Manual - page 22
ZONE 2 SETUP
The Zone 2 feature allows one to simultaneously experience in a different
zone of the house selected audio from any of the enabled Sources as well
as from Front Input and Media Player.
VOLUME
Zone 2 have Fixed and Variable volume control. When set to “Variable”
and while at the “Zone Controls” menu OSD, the Zone 2 Volume level can
be adjusted using the AVR 4’s [D/F] or the corresponding front panel
navigation buttons or directly via ZR 7’s [VOL d/f].
On the other hand, if Volume is set to “Fixed”, the Zone 2 Volume is set to
a preset dB level and thereafter the Zone’s volume can be varied via the
volume control of the separate amplifier it is fed into.
See discussion also about “Zone Controls” at the Main Menu.
AMPLIFIER SETUP
If the surround back speakers are not used in the main zone, their surround
back amplifier channels could be assigned for Back, Height 1, Height 2,
Zone 2 and Front (Bi-Amp) use.
The Surround Back amplifier is configurable through the following settings
Back: Assign as surround back speakers.
Front (Bi-Amp): Provide a bi-amp mode for the Main Front speakers
(Left and Right) speakers thus reproducing the Front Left and Front
Right amplifier channel outputs.
Zone 2: Assign the surround back amplifier channels to supply Zone 2
speaker level outputs from the surround back speaker terminals. Refer
also to the item about “ZONE 2 AT AUDIO PRE-OUT SURROUND BACK”
in the “ZONE CONTROLS” segment of the “OPERATION - USING THE
T 758 - MAIN MENU” section.
Height 1/Height 2: Assign as Height 1 or Height 2 speakers.
TRIGGER SETUP
The T 758 features a configurable +12V TRIGGER OUT that can be used to
activate a component or system it is fed into. It is used to turn on/off other
compliant devices.
The T 758’s +12V TRIGGER OUT is dependent on which mode it is
associated with. There are three choices where the +12V TRIGGER OUT can
be assigned and these are - Main, Zone 2 and Source Setup.
Main: +12V DC is available at +12V TRIGGER OUT when the T 758 is at
powered state.
Zone 2: When the Zone 2 is at powered state, +12V DC is available at
+12V TRIGGER OUT.
Source Setup: If Trigger Output is linked to “Source Setup”, +12V DC
is available at +12V TRIGGER OUT whenever the particularly assigned
Source is selected.
DELAY
The availability of +12V DC at Trigger Out can be regulated. If it is desired
that +12V DC is available without delay the moment Trigger Out is linked
to its assigned setting, set Delay to 0s. Otherwise, one can select through a
delay time of 1s to 15s.