    Hexadecimal data entry to enter a hexadecimal digit enter the following: a= d= b= e= c= f= set key press this key before entering a program- ming block number. Xp-600 programming instructions ® dealer program mode - keypad key definition note: these programming instruction are intended to be used in...

  • Page 2

    2 7\shv ri 3urjudpplqj %orfnv led programming block enable features by pressing the key that corresponds to the associated feature; the led will turn on. To disable a feature press the key again; the led will turn off. To disable all features within a led type programming block press the key; all le...

  • Page 3

    3 viewing data in programming blocks to view data within a programming block, enter the program block number, then press the key, continue pressing the key until all digits within the programming block have been viewed. Data will be displayed in the binary format shown in the table below: zone led o...

  • Page 4

    4 =rqh )hdwxuhv ul default off off on off off off 00 exit/entry zones zone 1 zone 2 zone 3 zone 4 zone 5 zone 6 default off off off off off off 01 home/away with delay zones zone 1 zone 2 zone 3 zone 4 zone 5 zone 6 default off off off off off off 02 exit/entry follower zones zone 1 zone 2 zone 3 zo...

  • Page 5

    5 zn 1 led on = momentary keyswitch arming 6\vwhp 7lphv entry delay, seconds (0) (3) (0) maximum entry 255 11 entry delay exit delay, seconds (0) (4) (5) maximum entry 255 10 exit delay bell time-out, minutes (0) (0) (5) maximum entry 255 12 burg (steady) output time-out bell time-out, minutes (0) (...

  • Page 6

    6 7hohskrqh 1xpehu 3urjudpplqj 30 subscriber id number [0] disabled [1] ademco slow [2] radionics slow [3] silent knight fast [4] universal high speed [5] reserved [6] point id [7] pager 32 receiver format (4) 31 telephone number 1 n ote : requires features to be enabled, see block [20]. N ote 1: a ...

  • Page 7

    7 %dfnxs 7hohskrqh 3urjudpplqj 3djhu 3urjudpplqj 47 leading digits 48 trailing digits (0) (0) (0) (0) *(c) *see note 1 dialing prefix for telco 1, telco 2 & telco 3. 40 subscriber id number (telco 2) 41 telephone number 2 [1] ademco slow [2] radionics slow [3] silent knight fast [4] universal high s...

  • Page 8

    8 7hohskrqh 1xpehu 3urjudpplqj 50 subscriber id number [0] disabled [1] ademco slow [2] radionics slow [3] silent knight fast [4] universal high speed [5] reserved [6] point id [7] pager 52 receiver format (4) 31 telephone number 3 n ote : requires features to be enabled, see block [20]. N ote 1: a ...

  • Page 9

    9 5hsruw &rghv 60 zone report codes zone 1 alarm code (3) zone 2 alarm code (3) zone 3 alarm code (3) zone 4 alarm code (3) zone 5 alarm code (3) zone 6 alarm code (3) the second digit of the re- port code is the number of the zone that is reporting. For example zone 5 report code (default of 3) wou...

  • Page 10

    10 :luhohvv 7udqvplwwhuv : 71 zone 1 rf id # point : 72 zone 2 : 73 zone 3 : 74 zone 4 : 75 zone 5 : 76 zone 6 enter the rf id# located on the transmitter, key fob and smoke detector labels. Rf id # xxxxxx:x enter the point number to be associated with the zone. If only one point of gem-trans2 is us...

  • Page 11

    11 'rzqordglqj (0) (9) maximum entry 15 91 ring count 93 auto download id number (4) (5) (6) (7) 94 dealer code 'hdohu 3urjudpplqj (1) (2) (3) (4) 95 user 1 code 90 callback telephone number (9) 98 number of re-dials default off off on off 92 downloading features zn 1 led on = ring method zn 2 led o...

  • Page 12

    12 -4 +5 +6 xp-600 terminals 1 2 +3 gem-recv-xp8 16 vac 20 va transformer napco trf12 (or equivalent see wi850a). Class 2 transformer. Do not connect to switched outlet. Red + black e1 e2 rechargeable battery 12 vdc 4ah or 7ah this equipment should be installed in accordance with chapter 2 of the na...