NAPCO GEM-P400 Installation Instructions Manual

Other manuals for GEM-P400: Using Manual
Manual is about: CONTROL PANEL/COMMUNICATOR

Summary of GEM-P400

  • Page 1

    Gem-p400 installation instructions control panel/communicator wi879a 8/97 © napco 1997 ® wi879a page 1 tuesday, september 16, 1997 08:16.

  • Page 2

    2 wi879a gem-p400 installation instructions *hqhudo ,qirupdwlrq the gemini gem-p400 control panel provides up to 4 hardwired/wireless zones. Up to four 4-digit user codes can be programmed. Ambush, when selected, uses user 4 code as an ambush code. The gem-p400 is wireless ready. When used with a ge...

  • Page 3

    3 6shflilfdwlrqv &xuuhqw 9rowdjh 5dwlqjv alarm output ---------------------------burg: 12 vdc, 2a (max.) fire: 12 vdc, 65 ma output current limiting --------------burg/fire: 2.25 a aux power: 750 ma combined standby current: --------350 ma maximum (remote pwr, aux output, pgm) 4 hour standby:-------...

  • Page 4

    4 wi879a gem-p400 installation instructions 4 zone control panel keypad zone doubling resistors (2.2k & 3.9k) operating instructions gem-p400 programming instructions gem-p400 gem-p400 gem-rp4 zdr oi230 wi880a 2ughulqj ,qirupdwlrq /lvwlqjv dqg $ssurydov ul household burglary warning system control u...

  • Page 5

    5 3urjudpplqj wkh 3dqho refer to gem-p400 programming instructions (wi880a) defaulting the panel 1. Remove power from the panel. 2. Remove all wiring from terminal 15 (pgm) and terminal 3. 3. Connect terminal 15 (pgm) to terminal 3. 4. Apply power to the gem-p400 control panel. 5. After a few second...

  • Page 6

    6 wi879a gem-p400 installation instructions ,qvwdoodwlrq mounting the panel mount the panel close to an unswitched ac source, a cold-water pipe ground, and a tele- phone line connection. Mounting the keypad a keypad should be located near an exit/entry door. To remove the keypad from the backplate, ...

  • Page 7

    7 pgm wiring the pgm is a switched negative output that is activated depending on the programming op- tion(s) that have been selected [08], [23] - [25]. Connect the device controlled by the pgm be- tween +pwr and the pgm terminal (maximum load of 50 ma). .H\sdg 2shudwlrq keypad zone leds indicate zo...

  • Page 8

    8 wi879a gem-p400 installation instructions arming/disarming with a keyfob the system can be armed by pressing the key, and disarmed by pressing the key on the keyfob. Zones programmed as exit/entry follower zones can be bypassed when the or keys on the keyfob have been pro- grammed for interior [81...

  • Page 9

    9 full setting the system with automatic bypassing - home/away with delay zones from the keypad press to return protection to home/away with delay zones that have been automatically bypassed. Three min- utes are allowed to walk through exit/entry and exit/entry follower zones. Using a keyfob (gem-kf...

  • Page 10

    10 wi879a gem-p400 installation instructions while in user program mode the armed, status and system trouble leds will continue to flash, follow the example to program user 2’s code to 1923. User mode programming example: 1. Press , zone 2 led will flash 2. Enter , zone 2 led will continue to flash ...

  • Page 11

    11 'hdohu &rppdqgv download (programming re- quired) establish a connection between the pcd phone line and the control panel phone line. When ready, tell the installer to arm, then disarm. Then enter in order to establish a connec- tion. Phone connection to installer will go "dead" as downloader and...

  • Page 12

    12 wi879a gem-p400 installation instructions lay, also program zones as exit/entry fol- lower zones [02]. To return protection to zones of this type, press from the keypad or or from a keyfob. Program the keyfob aux 1 or aux 2 button for full set [81-7]. [02]exit/entry follower zones entry delay all...

  • Page 13

    13 [08]pgm output enables the pgm output on a zone trip for each zone selected. The pgm output will remain on until reset. 6\vwhp 7lphv [10]exit delay the delay time which permits exit through an exit/entry zone [00] after the system is armed, allows a user to leave the premises without setting off ...

  • Page 14

    14 wi879a gem-p400 installation instructions program user 4 arm/disarm code. Select reporting to telco 1 [36-2] or telco 3 [56-2]. [21]keypad features 2 (1) audible panic - keypad panic will not turn the bell on unless this option is pro- grammed. (2) exit/entry with urgency - select to give an audi...

  • Page 15

    15 (3) panic - program to activate the pgm on a panic alarm. (4) test timer - program to activate the pgm during a test timer report. [25]programmable output features 3 (1) ac fail - program to activate the pgm on the loss of ac. (15 minute delay) (2) low battery - program to activate the pgm on a l...

  • Page 16

    16 wi879a gem-p400 installation instructions pager alarm data is the same as 4/2 format with the exception that the 2 digit report code is transmitted before the 4 digit sub- scriber id. [33]receiver options (1) 2300 hz hs/kissoff - select 2300 hz handshake and kissoff. (2) sumcheck - only used for ...

  • Page 17

    17 (4) test timer - program to activate a test timer report. [37]system reporting, telco 1 (1) ac fail report - program to activate an ac fail report (15 minute fixed report delay). (2) low battery report - program to acti- vate a low battery report. (3) *trouble report - program to activate a troub...

  • Page 18

    18 wi879a gem-p400 installation instructions [46]communicator features 2 (1) no dial tone detection - program to disable dial tone detection for telco 1, telco 2 and telco 3. (2) 2:1 rotary dialing - changes the make break ratio when rotary dialing from 1.5:1 to 2:1. (3) backup if - if backup report...

  • Page 19

    19 [66]ambush report code program a 2-digit report code for ambush. To send an ambush report, program a user code for user 4, program report user 4 as ambush [20-4] and select reporting for telco 1 [36-2] and/or telco 3 [56-2]. (qkdqfhg &rppxqlfdwru )hdwxuhv [67]telephone number 1 (1) opening after ...

  • Page 20

    20 wi879a gem-p400 installation instructions [71-74] wireless transmitters enter the rf id# and the point number that is to be mapped to the zone. Programming example map point 1 of a window door transmitter with an rf id# of 0012b0:0 to zone 3. 1. Enter dealer mode. 2. Enter ( beeps) (beeps) 3. Ent...

  • Page 21

    21 7 full set system program a 7 in the aux 1 and/or aux 2 option to fully set the system when the and the or buttons on the keyfob are pressed, or when the or buttons are pressed when the system is armed with exit/entry follower zones or home/away with delay zones that have been bypassed. 8 interio...

  • Page 22

    22 wi879a gem-p400 installation instructions site at the site perform the following three steps: 1. Arm the panel. 2. Disarm the panel. 3. Enter . The panel will now call the download computer running pcpreset. Pcpreset will answer the call, establish a connection, and then download the account that...

  • Page 23

    23 6\vwhp 7urxeohv use the system trouble chart on the following page to determine the specific system trou- ble(s). During normal panel operation the system trouble led has the following two modes of operation: steady 1-7 possible trouble groups, ac is present flashing 1-7 possible trouble groups, ...

  • Page 24

    24 wi879a gem-p400 installation instructions keypad beeps or system flashes zone led on system trouble condition cause/action 1 beep 1 ac power failure this trouble will occur if ac power is not present. Ensure that the transformer is connected to an unswitched power source. 2 low battery if there h...

  • Page 25

    25 7urxeohvkrrwlqj 1. The bell output drops to about 3 volts in alarm. The battery/bell circuit is protected by a pc board trace which may have burned open by reversal of the battery leads. It is on the back of the pc board just adjacent to the red & black battery leads. Send in for ser- vice if thi...

  • Page 26

    26 wi879a gem-p400 installation instructions 8. How do i remove keypad sounder on alarm? The keypad sounder follows the burg out- put. If you need to remove the keypad sounder, then you must remove the burg output from that zone. 9. Transmitters not responding? Open transmitter case - keypad should ...

  • Page 27

    27 16 vac 20 va transformer napco trf12 (or equivalent see wi879a). Class 2 transformer. Do not connect to switched outlet. -4 +5 +6 1 2 +3 gem-recv-xp8 red black e1 e2 rechargeable battery 12 vdc 4ah or 7ah all outputs are current limited warning to prevent risk of electric shock disconnect telepho...

  • Page 28

    28 wi879a gem-p400 installation instructions napco limited warranty napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, at its option, re...