NAPCO GEM-P400 Installation Instructions Manual - page 10
10
WI879A GEM-P400 Installation Instructions
While in User Program Mode the Armed, Status
and
System Trouble LEDs will continue to
flash, follow the example to program User 2’s
code to 1923.
User Mode Programming Example:
1. Press
, Zone 2 LED will Flash
2. Enter
, Zone 2 LED
will continue to flash until the 4th digit is
entered. The keypad will beep 4 times con-
firming a valid entry (Zone LED steady).
Deleting a User Code
Press the number of the User to be deleted, the
zone LED will be flashing indicating that the user
has been selected. Press the
key, the LED
associated with the user will now be OFF.
Exiting User Program Mode
To exit User Program Mode press the
key.
*(03 &RPPDQGV
User Commands
Bell Test
Enter this command to turn on the Bell, keypad
sounder and keypad LEDs for 2 seconds. The
battery is tested during a Bell Test, and auto-
matically every *24 hours to ensure proper
battery operation under load. The Alarm output
requires a battery in order to supply the speci-
fied output. If the battery cannot sustain the
load, a low battery indication will be displayed.
A battery test is also performed on power-up
after a 3 minute delay.
Easy Arm
Press this key to arm the panel. To disarm
the panel a valid Arm/Disarm code must be
entered. Requires
Easy Exit/Easy Arm [21-2]
to be enabled.
Interior
Enter this command to bypass all
Exit/Entry
Follower Zones or Home/Away Zones (only if
the system is programmed exclusively for
Home/Away with Delay zones).
Instant
Enter this command before or after arming to
remove the entry delay on
Entry/Exit Zones.
The keypad ARMED LED will flicker rapidly.
Faulting a
Exit/Entry Zone will result in an imme-
diate alarm.
Chime ON/OFF
Enter this command to turn chime ON/OFF. The
Keypad will chime on any zone that has not
been
selected as an
Exit/Entry Follower Zone, Home/
Away with Delay Zones, or 24 Hour Zone.
+ User 1 Code - User Program
Mode
Keypad Sleep Mode ON/OFF
Enter this command to turn the keypad sounder
ON/OFF. When the keypad is in Sleep mode all
keypad sounds will be silenced except for key-
pad feedback beeps and Keypad Sounder on
Alarm.
User Commands - Optional
Easy Exit
If enabled in Dealer programming, enter this
command while the panel is Armed to allow 3
minutes to exit the premises through
Exit/Entry
and
Exit/Entry Follower Zones.
Access on PGM
If enabled in Dealer programming, enter this
command to activate the PGM output (Terminal
15) for 5 seconds.
Zone LED Meaning
OFF
User Arm/Disarm Code not programmed
Flashing
User Arm/Code is currently being programmed
Steady
User Arm/Disarm Code has been programmed
TABLE
4
Z
ONE
L
ED
D
EFINITION
-U
SER
P
ROGRAM
M
ODE
Wi879a
page 10
Tuesday, September 16, 1997 08:16