NAPCO Gemini GEM-P9600 Installation Instructions Manual

Manual is about: CONTROL PANEL/COMMUNICATOR

Summary of Gemini GEM-P9600

  • Page 1

    Installation instructions hardwire wireless g e m - p 9 6 0 0 control panel/communicator wi742e 2/04 © napco 2004 r "k series" gem-k2as r computerized security system armed status system armed 01/01/97 12:00am 1 2 4 3 5 6 7 8 9 0 a b c d e f g next/yes prior/no area gemini ready ac on ready ac on r ...

  • Page 2

    Changes from previous edition the following changes have been made to this manual (wi742e) since the last edition (wi742d): page 3, added an "important note" with regard to the control panel and keypad version numbers. Page 30, updated error codes with 2 new codes: "e40-00 - rf self test fail. Recei...

  • Page 3: Important Note

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 3 important note this manual supports the keypad programming of the gem-p9600 control panel with the napco "classic" gem- rp1cae2, gem-rp2ase2, gem-rp3dgtl and gem-rp4rfc/gem-rp4c keypads as well as the gem-k1ca, gem- ...

  • Page 4

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 4 table of contents refer to accompanying gem-p9600 programming instructions (wi777 and wi1185) for programming information. Changes from previous edition ........................ 2 important note ........................

  • Page 5

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 5 introduction general description napco's gemini gem-p9600 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up ...

  • Page 6

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 6 ! 800 event log. ! Overview mode permits monitoring and control of total system from one keypad. ! Guard-tour programmable for start time, tour length, and check points (tour stations). ! Two programmable entry delay...

  • Page 7

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 7 specifications gem-p9600 panel dimensions: 12 3/8" x 13 7/8" x 3 ½" (h x w x d) without cover operating temperature: 0-49°c (32-120°f) input power: 16.5vac via class 2 plug-in 40va or 50va transformer loop voltage: 1...

  • Page 8

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 8 optional accessories and peripherals eol130: 2-wire fire zone resistor, 130w, 3w eol2.2k: end-of-line resistor assy., 2.2k ft2200: end-of-line relay/resistor supervisory module gem-dt: wireless dual-technology sensor...

  • Page 9

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 9 summary of ul requirements residential ! Recognized limited-energy cable for initiating, indicating and supplementary circuits. ! Initiating loops supervised if longer than 3 feet ! Ft2200 end-of-line relay for fire ...

  • Page 10

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 10 installation mounting control panel choose a mounting location accessible to (a) a continuously-powered ac source, (b) system ground, a steel or copper ground rod, ideally no further away than 10 feet, and (c) telep...

  • Page 11

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 11 wiring wire keypad(s), zones, expansion zone modules and output devices as shown on the wiring diagram. Note that the wiring diagram contains important information not available elsewhere in this manual. Adding expa...

  • Page 12

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 12 ul commercial-burglary installations the gem-p9600m can be used as part of a ul central station grade c, b, or a installation. Normally, a digital communicator is classified as grade c and may be classi- fied grade ...

  • Page 13

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 13 testing the system after installation is completed, test the system as follows. ! 1. Call the central station to inform them of the test. ! 2. Initiate an alarm, preferably on a zone that activates a steady siren, a...

  • Page 14

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 14 wiring connections auxiliary alarm output auxiliary output can be activated depending on the programming options selected (see gem- p9600 programming instructions). Connect the device controlled by the programmable ...

  • Page 15

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 15 earth ground note: do not use a gas pipe, plastic pipe or ac ground connections. Connect the control panel earth ground screw through a no. 16 awg. Or larger wire to a metal cold-water pipe. Do not use a gas pipe, p...

  • Page 16

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 16 basic zone configuration the basic zone configuration for the gem-p9600 is 8 zones. Connect as shown above to terminals 16-27. Normally closed (n.C.) devices may be wired in series or normally open (n.O.) devices ma...

  • Page 17

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 17 4-wire smoke detectors 4-wire smoke detector wiring the gem-p9600 can use conventional 12 vdc 4-wire smoke detectors. To use them, the select fire zone programming option and do not select 2-wire smoke detector pro-...

  • Page 18

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 18 connect the model 368 cord as follows: 30 (red = telco tip), 31 (green = telco ring), 32 (gray = home tip) and 33 (brown = home ring). Insert the modular plug into an approved usocrj31x jack (or a ca31a jack for can...

  • Page 19

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 19 keypad configuration mode this section will focus on configuring the gem-rp1cae2/gem-k1ca and gem-rp2ase2/gem-k2as keypads. If there is more than one keypad in the system, only keypad no. 1 may be used for programmi...

  • Page 20

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 20 compatibility number the compatibility number is a 4-digit security code that, if programmed into both the control panel and each gem-rp1cae2/gem-k1ca keypad, dedi- cates the keypad to only that panel. That is, (a) ...

  • Page 21

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 21 configuring the gem-rp2ase2/gem-k2as and gem-rp3dgtl/gem-k3dgtl keypads up to 7 gem-rp2ase2/gem-k2as and/or gem-rp3dgtl/gem-k3dgtl keypads may be connected to the panel (keypads 1–7). Each must be configured for a k...

  • Page 22

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 22 basic operation this section provides a brief overview of system operation. For detailed operation, refer to the user's guide furnished with the keypad (see page 8 for a complete listing) and to the keypad programmi...

  • Page 23

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 23 g0 will clear the entry at the cursor. When programming zone descriptions, buttons 3 and 6 will scroll not only through numbers 0-9, but through the alphabet and a series of punctuation marks and symbols as well. (r...

  • Page 24

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 24 arming in stay mode stay mode provides partial protection by allowing free movement within the premises, while still protecting the perimeter zones. Exit/entry doors are provided with exit/entry delays. A "classic" ...

  • Page 25

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 25 2. Press the g button, then the u or d button. 3. Arm or disarm the selected area using your user code (the user code must be valid for that area). 4. To return the keypad to its "home" area, press the g button, the...

  • Page 26

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 26 ditions will then be stored in the alarm history log and the total event log (see history log). Alarm indication ! If programmed to silence an alarm, enter a valid user code and press the u button. The keypad must h...

  • Page 27

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 27 rect the problem, then press the c button to restore the "system ready" condition. Display op/cl ! Napco's pcd-windows quickloader software offers a comprehensive array of programmable opening and clos- ing suppress...

  • Page 28

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 28 fault find this troubleshooting aid will help the installer locate swingers. When accessed, two things occur: ! The loop response of each zone is set for the fastest response time. ! Causing or repairing a fault act...

  • Page 29

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 29 may be canceled by arming and disarming the panel. Display auto arm schd (not for ul installations) press the yes button to display the autoarm schedule programmed by the pcd-windows software. Use next and prior but...

  • Page 30

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 30 keypad messages the gem-rp1cae2/gem-k1ca keypad can display the following messages. The gem-rp2ase2 and gem-k2as keypads will dis- play similar abbreviated messages that may scroll through two screens. System ready ...

  • Page 31

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 31 glossary note: displayed messages shown are for the gem-rp1cae2 and gem-k1ca keypads. Gem-rp2ase2/gem-k2as and gem-rp3dgtl/gem-k3dgtl messages are similar but abbreviated. Refer to the appropriate gem-p9600 programm...

  • Page 32

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 32 alarm on day zone see day zone alarm outputs (see wiring diagram for ul requirements.) the gem-p9600 has three form-c relay outputs: burglary, auxiliary and reset. Each has a related jumper (b, a, and c, respectivel...

  • Page 33

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 33 ambush code for an ambush report to be sent. When “enable global ambush” is selected and no ambush code has been en- tered and the keypads have been selected for ambush, then the ambush code will default to “99”. An...

  • Page 34

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 34 tempts will be made to reach the second telephone number. Enter subscriber identification numbers for telephone 2 and other infor- mation required for telephone 2. Also program backup report on telco 2. Any zone pro...

  • Page 35

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 35 follow the keypad sounder. This feature can be found on the options page of the pcd software, or you can program a bit value of 2 in the right hand side of location 2420 [!] [2]. “clean me tm ” smoke detector suppor...

  • Page 36

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 36 holdup = “4”; gas alarm = “7”; heat alarm = “8”; auxiliary alarm = “a” (keypad displays “0”); 24-hour aux. Alarm = “b”. Pager formats. The control panel has provisions for dialing a pager phone number. The panel wil...

  • Page 37

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 37 dial-tone detection skip automatic dial-tone detect the panel features automatic dial-tone detection to ensure that a dial tone is present before the communicator dials. To skip this feature, program an “8” in locat...

  • Page 38

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 38 disable code required for function mode level 1 intended primarily for residential applications, this feature eliminates the user code requirement to access the function mode (for level-1 users only), rendering the ...

  • Page 39

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 39 enable burg output warning on entry causes the burglary output to “chirp” if the entry door is opened within 60 seconds after exit time has elapsed. This feature may be useful in cases where a keypad is not within a...

  • Page 40

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 40 exit/entry follower a zone programmed as an exit/entry follower will ignore detection during the exit delay, and only during entry delay if the exit/ entry zone is entered first. Thus, detection devices (passive inf...

  • Page 41

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 41 next time the panel is disarmed. If “auto interior bypass” is programmed, all interior zones will automatically be bypassed if the exit/entry doors are not opened during exit delay. If d is pressed while armed stay,...

  • Page 42

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 42 keyfob disarm activates entry lighting disarming with a keyfob can activate remote relays or x-10 devices by programming the event entryrelay area1, or entryre- lay area2 on the external relay control screen. This e...

  • Page 43

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 43 loop response (750ms required for ul installations) loop response is the amount of time in milliseconds (ms) that a normally-closed circuit must remain open, or a normally-open circuit must remain closed, to trigger...

  • Page 44

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 44 by the central station to verify that the subscriber has responded and disarmed the panel. If opening report only after alarm report is selected, also select opening report for each user. Opening/closing reporting f...

  • Page 45

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 45 for each telephone number used, but a different format may be assigned to each. Refer to backup report on telco 2 and report telco 3 to determine whether or not telephones 2 and/or 3 will be programmed. Call the cen...

  • Page 46

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 46 resound on wireless smoke low battery if a wireless smoke detector low battery is detected, it will re-sound the trouble at the keypad every 4 hours when disarmed and every 12 hours when armed, until the condition i...

  • Page 47

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 47 1. Program the selected zone(s) (1–6) for 2-wire smoke detec- tors and fire. 2. Cut out the 2700Ω resistor (color code: red/violet/red) associ- ated with the selected zone(s). See table below. 3. Install a 130Ω resi...

  • Page 48

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 48 subscriber identification numbers if reporting openings and/or closings, program subscriber opening/closing identification numbers for each area for each tele- phone number used. If reporting events, program subscri...

  • Page 49

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 49 telemetry trouble if any device connected to the on-board serial port (such as a home automation system or aes radio) fails to respond to a poll by the control panel, a telemetry trouble system trouble will result. ...

  • Page 50

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 50 time selection the following times are programmable: any timeout up to those shown in the foregoing table may be programmed. Note that each of the above times is pro- grammed in two locations. The first location has...

  • Page 51

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 51 trouble (open and/or short circuit) on a day zone is indicated by a pulsing sounder; display the day zone(s) in trouble on the lcd. Keypad indications are reset by the c button unless reset day zone with arm/disarm ...

  • Page 52

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 52 zone anding, groups 1–8 (not for ul installations); enable local alarm on first zone “and” trip (not for ul installations) up to 8 groups of at least two zones each can be “and”ed, wherein the system will go into al...

  • Page 53

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 53 standby-battery calculation worksheet use the procedure given below to determine the required standby battery capacity in ampere-hours (ah). Note: it is not totally ac- curate to merely multiply the combined standby...

  • Page 54

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 54 wiring legend should removal of the circuit board be necessary, use this wiring legend to relocate wire leads to their proper terminals. Enter wire identification number or color code in wire number column and enter...

  • Page 55

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 55 keypad programming modes note: 1. Functions that are not active, not programmed and/or not applicable to user’s authority level will be suppresses and will not display. 2. Due to space constraints, gem-rp2ase2/gem-k...

  • Page 56

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 56 keyp a d progr a m m ing modes note: 1. Functions that are not active, not programmed and/or not applicable to user’s authority level will be suppresses and will not display. 2. Due to space constraints, gem-rp2ase2...

  • Page 57

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 57 keyp a d progr a m m ing modes easy menu program mode (a) minimum level required to access function (b) level 3 code with appropriate option (c) requires dealer code (d) not available in gem-rp2ase2/gem-k2as keypads...

  • Page 58: Notes

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 58 notes.

  • Page 59

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 59 keyp a d progr a m m ing modes keypad configuration mode press a button enter factory code: 11123 configure: • keypad beep on/off • entry sounder • keypad address 01 • new compat# 0000 ** • ezm address 00 • zone res...

  • Page 60

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 60 gem-p9600 wiring diagram.

  • Page 61

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 61 cp-01 quick reference chart--sia false alarm reduction feature description programming address location cp-01 features are enabled with one global selection in the panel. Enabled in ez programming exit delay. Minimu...

  • Page 62

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 62 duress code. The panel will not allow duplicate user codes to be programmed. Every user program code may now be selected as an ambush code for area 1 or area 2 by entering a _5 in the area 1 options or area 2 option...

  • Page 63

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 63 gem-p9600 factory default description the factory program of the gem-p9600 will change with the release of the new version that complies with security industry as- sociation false alarm reduction control panel-01 st...

  • Page 64

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 64 statement for canadian models notice: the canadian department of communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, ...

  • Page 65

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 65 fcc statement this equipment generates and uses radio-frequency energy and, if not installed and used properly, that is, in strict ac- cordance with the manufacturer's instructions, may cause interference to radio a...

  • Page 66: Notes:

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 66 notes:.

  • Page 67: Notes:

    L napco security systems x gem-p9600 installation instructions wi742e 2/04 ! Page 67 notes:.

  • Page 68

    X gem-p9600 installation instructions l napco security systems wi742e 2/04 ! Page 68 napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in ma- terials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period...