  • Page 1

    1 w415-0496 / b / 08.10.05 w415-0496 / b / 08.10.05 northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.

  • Page 2

    2 w415-0496 / b / 08.10.05 what to do if you smell gas warnings & safety precautions northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.

  • Page 3

    3 w415-0496 / b / 08.10.05 warning • the stove is a vented gas-fired heater. Do not burn wood or other materials in this stove. • adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children...

  • Page 4

    4 w415-0496 / b / 08.10.05 napoleon products are manufactured under the strict standard of the world recognized iso 9001 : 2000 quality assurance certificate. Napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The...

  • Page 5

    5 w415-0496 / b / 08.10.05 expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit i...

  • Page 6

    6 w415-0496 / b / 08.10.05 maintain these minimum clearances to combustibles: a. 4" b. 2" * c. 2" stove should not be installed directly on carpeting . Minimum 48" from stove top to ceiling to ceiling from stove top .......................................48" horizontal vent sides and bottom ...........

  • Page 7

    7 w415-0496 / b / 08.10.05 blower installation blower ( see location and clearances ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower. 3. Connect the black blower wire to the black wire ...

  • Page 8

    8 w415-0496 / b / 08.10.05 air terminal installations ***** recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** it is recommended to use a heat shield and to maximize the distance to vinyl clad soffits. *** *** *** *** *** the periscope gd-201 requires a minimum 18 inc...

  • Page 9

    9 w415-0496 / b / 08.10.05 use only wolf steel, simpson dura-vent, selkirk direct temp or american metal amerivent venting components. For simpson dura-vent, selkirk direct temp and american metal amerivent, follow the installation procedure provided with the venting components. All outer pipe joint...

  • Page 10

    10 w415-0496 / b / 08.10.05 use the gd201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace,...

  • Page 11

    11 w415-0496 / b / 08.10.05 elbow vent length values definitions horizontal termination required vertical rise in feet (v t ) calculated horizontal vent run plus offsets in feet (h t ) figure 5 45º figure 6 90° h 1 h 2 when (h t ) t ) for the following symbols used in the venting calcula- tions and ...

  • Page 12

    12 w415-0496 / b / 08.10.05 v 1 horizontal termination see graph to determine the re- quired vertical rise v t for the re- quired horizontal run h t . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: formula 1: h t t formula 2: h t + v t figure 7 requir...

  • Page 13

    13 w415-0496 / b / 08.10.05 vertical termination example 3: v 1 = 5 ft v 2 = 10 ft v t = v 1 + v 2 = 5 + 10 = 15 ft h 1 = 3 ft h 2 = 2.5 ft h r = h 1 + h 2 = 3 + 2.5 = 5.5 ft h o = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 h t = h r + h o = 5.5 + 5.4 = 10.9 ft h t + v t...

  • Page 14

    14 w415-0496 / b / 08.10.05 h 1 vertical termination for vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: formula 1: h t t formula 2: h t + v t when (h t ) > (v t ) simple venting configurations see graph to determine the required vertical rise v t fo...

  • Page 15

    15 w415-0496 / b / 08.10.05 this application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". Important: for optimum performance, the stove pipe should rise ¼" per foot of...

  • Page 16

    16 w415-0496 / b / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in figure 24. Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run. Us...

  • Page 17

    17 w415-0496 / b / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flex- ible liner to the stove. Secure with 3 screws and flat wash- ers. Seal the joint and screw holes using high tempera- ture sealant. 3. Run a be...

  • Page 18

    18 w415-0496 / b / 08.10.05 1.Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. Finishing glass door installation and removal cast front ...

  • Page 19

    19 w415-0496 / b / 08.10.05 log placement logo placement remove the backing from the the logo and position onto the control door as shown. It is not necessary to remove the cast front, however, this will make for a more simple log installation. In order to assemble the log set, the door must be remo...

  • Page 20

    20 w415-0496 / b / 08.10.05 purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door. The on-off switch is located on the back of the unit at the top right corner on model gds20. When lit for the first time, the fireplace will emit a...

  • Page 21

    21 w415-0496 / b / 08.10.05 adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Figure 34 figure 35 air shutter adjustment must only be done by a qualified gas installer! Figure 36 adjustments pilot burner adjustment venturi adjustment turn o...

  • Page 22

    22 w415-0496 / b / 08.10.05 contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your napoleon dealer or distributor. When ordering replacement parts always give the fol- lowing information: 1. M odel & s erial n umber o...

  • Page 23

    23 w415-0496 / b / 08.10.05 * warning: this is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by wolf steel ltd. Northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.

  • Page 24

    24 w415-0496 / b / 08.10.05 pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the c...

  • Page 25

    25 w415-0496 / b / 08.10.05 main burner goes out; pilot goes out. Refer to "main burner goes out; pilot stays on" thermocouple shorting or faulty. Vent re-circulating - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection. - replace thermoco...

  • Page 26

    26 w415-0496 / b / 08.10.05 w olf steel fir eplace ser vice histor y this fireplace must be serviced annually depending on usage. Date service t echnician name service performed special concerns dealer name northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.

  • Page 27

    27 w415-0496 / b / 08.10.05 notes northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.

  • Page 28

    28 w415-0496 / b / 08.10.05 notes northlineexpress.Com http://www.Northlineexpress.Com toll-free 1-866-667-8454.