    W415-0702 / 10.30.08 1 $10.00 w415-0702 / 10.30.08 installation and operating instructions wolf steel ltd., 24 napoleon rd., barrie, on l4m 4y8 canada • (705)721-1212 • fax(705)722-6031 www.Napoleonfireplaces.Com • ask@napoleon.On.Ca this heater has been tested to astm e 1509, ul 1482, ulc s627. Int...

  • Page 2: Warning

    W415-0702 / 10.30.08 32 a. Open the side doors on either side of the heater. B. On the right side of the heater are two latches. Release the latches by pulling the rear handle forward and disengaging the hook from the door frame. Swing open the viewing door. The front of the heater becomes very hot ...

  • Page 3: Warning

    W415-0702 / 10.30.08 33 to clean the burn pot, open the door and knock away any debris on the burn pot. If severely clogged, remove the burn pot to gain better access. If removing the burn pot set aside on a non-combustible surface. Once removed, discard all material that has accumulated in the burn...

  • Page 4: Warning

    W415-0702 / 10.30.08 34 the more frequently you clean out the fly ash, the more efficient your heater will burn. A. Open the viewing door. See “open main viewing door” section. B. Lift the burn pot out and set aside on a non-combustible surface. Remove the right and left louvres by lifting the louvr...

  • Page 5

    W415-0702 / 10.30.08 35 9.3.2 soot and fly ash formation the products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion occurs during startup, shutdown, or incorrect operation o...

  • Page 6: Warning

    W415-0702 / 10.30.08 36 9.3.6 check all seals 9.3.7 clean the vent check for air leaks around the door, glass, and ash pan and replace gaskets as required. Air leaks into the firebox will decrease the heater's performance greatly, leading to excessive soot, inefficient burning, and may even cause a ...