Napoleon SDO800 Installation Instructions And User Manual - page 11
9
3. Safety reverse force adjustment
4. Auto-close setting
5.Photo beam setting
6.
“K” - Button
Press „SET‟ button and hold on until the LED displays
„3‟. It‟s under force adjustment mode. Press „LIM-1‟
button
to increase the force and „LIM-2‟ button to
decrease the force. The maximum force is 9 and the
minimum is 1. Press „SET‟ button to confirm.
Press „LIM-1‟ button and hold on until the LED displays „-‟.
Press „LIM-1‟ button once, the auto-close time will increase 1
minute, the maximum time is 9 minutes. Press
„LIM-2‟ button
the auto-close time decrease 1 minute. The auto-close
function w
ill be turned off when LED displays 0. Press „SET‟
button to confirm.
Press „LIM-2‟ button and hold on until the LED displays‟11‟,
press „LIM-1‟ button the LED displays „H‟, photo beam
function is available.
Press „LIM-2‟ button the LED displays
„11‟ to cancel this function. When setting is finished, press
„SET‟ to confirm. When connecting pulsed quantity control
infrared sensor, wiring as below Fig. 1. When infrared
sensor is controlled by switch value, wiring as below Fig.2
Notice: Close the photo beam function when you don
’t
use photo beam sensor.
Press the
“K” button to operate the motor unit without a
transmitter.