National Vacuum Equipment 5314 Owner's Manual & Operating Instructions - Recommended Accessories
20
| 5314 Blower
www.natvac.com | 800.253.5500
NVE 607 Challenger Series
|
Parts List
RECOMMENDED ACCESSORIES
Exhaust Silencer
Positive displacement blowers are inherently noisy due to their design. NVE
offers compatible silencers for the exhaust to reduce decibel levels in the
operating environment.
If using a non-OEM silencer, it should be tested for effectiveness by blanking
off the inlet and monitoring exhaust gas temperature with the blower run-
ning for at least one hour. The blower should not exceed specified exhaust
gas temperatures.
Inlet Filter
The intake filters are designed to ensure maximum airflow efficiency why
keeping out unwanted debris. The filters supplied by NVE use a stainless
steel screen and can be cleaned.
Four Way Valve and Hoses
If it is intended to operate the blower in the pressure mode, a four way valve
will be required. The 4-way valve size should match the hose size used in the
application.
Pressure Relief Valve
If the blower is intended to be used in pressure mode then a pressure relief
valve is required. NVE recommends the use of Kunkle pressure relief valves
as they have been proven to work well and have sufficient flow capacity. The
valves we supply are factory set to 10 PSI and are sealed. We do not recom-
mend the blower to be operated over 10 PSI nor do we recommend the use
of imported relief valves.
Vacuum Relief Valve
Vacuum relief valves are not typically needed with NVE blowers. If the ap-
plication indicates the use of a vacuum relief valve would be called for, we
recommend you thoroughly test your blower system to confirm the desired
performance is reached (i.e. tank protection or overheat protection). We
would recommend the use of a high quality vacuum relief valve such as
Kunkle.