National Vacuum Equipment 5314 Owner's Manual & Operating Instructions - page 25
Manual is about: Vacuum/pressure blower
of
36
5314 Blower | 25
www.natvac.com | 800.253.5500
Oil Capacities and Recommendations
The initial oil change on the blower is after 500 hours of operation per the
maintenance table.
Size
Blower Oil Capacity - Do Not Overfill
Drive Side
Oz. (Liters)
Non-Drive Side
Oz. (Liters)
Total
4310
18 (.53)
8 (.24)
26 (.77)
747
18 (.53)
8 (.24)
26 (.77)
5314
13 (.38)
18 (.53)
31 (.92)
957
48 (1.42)
24 (.71)
72 (2.13)
1457
44 (1.30)
33 (.98)
77 (2.28)
Oil Fill
Sight Eyes