First Time Start-up:
Once the system is assembled, filled with water, and power is connected to the system
a few basic adjustments to the burner is required.
1.
Fill the auger with pellets by force starting the auger either through the controller
or directly via a 230V connection.
2.
When the augur appears full, run for an additional
15 min. to ensure correct weighing later.
3.
Activate the 6 min. test run in the controller
and collect the dispensed pellets with a plastic
bag.
4.
Using a kitchen scale, weigh the pellets from the test run and enter the amount
into the controller under
"Auto calculation" Repeat again after 7 days!
5.
Adjust minimum output as low as possible, typically 10% of the burner's rated
output (i.e. if 20kW, set to 2.00kW). If the chimney draft is high, adjust
the minimum output up until you have a stable flame at 10% power.
6.
Once the burner is activated an ignition will be made.
After approx. 20 minutes the burner will
reach a nominal output (100%). If
necessary lock the burner output at 100%.
Now you can perform an evaluation as to
whether the fan is providing suitable supply
of air to the flame.
If necessary, adjust in the fan menu.
The flame at 100% should fill the entire width
of the grate, have redish spikes, and reach the opposite wall.
7.
Lock the burner to 50% power.
Wait 5 minutes for the flame to
stabilize. Again, assess fan performance
in relation to the flame.
The flame at 50% should be approx. 10 cm
out of the burner and is yellowish in color.
8.
Lock the burner to 10% power.
Wait 5 minutes for the flame to
stabilize. Assess fan performance
in relationship to the flame.
The flame at 10% should be small and short.
The photo sensor reading may fluctuate, however,
it should not have a 0 LUX reading for a
period >10 sec. If the chimney draft is too high, increase the minimum effect of the
burner to increase flame size.