NCE Mini-Panel Instruction - page 11
Command format of the Mini Panel
The table below describes the hex bytes stored in the memory locations for each command
nop - no-operation, just execute next
command
1111 1111
1111 1111
ff
unused
---- ----
---- ----
d0-fe
set accessory/signal address 1-2044
aaaa aaaa
1100 1aaa
c8-cf
macro 0-255
nnnn nnnn
1100 0111
c7
not used
11xx xxxx
1100 0110
c6
if input nnnnn not active skip the
next command
101n nnnn
1100 0110
c6
if input nnnnn active skip the next
command
100n nnnn
1100 0110
c6
unused
011x xxxx
1100 0110
c6
link to execute commands for input
nnnnn
010n nnnn
1100 0110
c6
wait until input nnnnn not active, 0
not valid
001n nnnn
1100 0110
c6
wait until input nnnnn active, 0 not
valid
000n nnnn
1100 0110
c6
delay in 1/4 second increments
nnnn nnnn
1100 0101
c5
loco detected in block 0-255
nnnn nnnn
1100 0011
c4
f28->f21
ffff ffff
1100 0011
c3
f20->f13
ffff ffff
1100 0010
c2
set short loco address
1aaa aaaa
1100 0001
c1
function group 3 f12,f11,f10,f9
0111 ffff
1100 0001
c1
function group 2 f8,f7,f6,f5
0110 ffff
1100 0001
c1
function group 1 f0,f4,f3,f2,f1
010f ffff
1100 0001
c1
stored loco 28 speed forward (0-28
valid)
001s ssss
1100 0001
c1
stored loco 28 speed reverse (0-28
valid)
000s ssss
1100 0001
c1
stored loco 128 speed forward
1sss ssss
1100 0000
c0
stored loco 128 speed reverse
0sss ssss
1100 0000
c0
delay in 4 second increments
nnnn nnnn
1011 1111
bf
set OPs signal CV data (set CV number
first)
dddd dddd
1011 1110
be
set OPs accy CV data (set CV number
first)
dddd dddd
1011 1101
bd
set OPs loco CV data (set CV number
first)
dddd dddd
1011 1100
bc
set OPs CV num. 1-1024 (set loco/accy
addr 1st)
nnnn nnnn
1011 10nn
b8-bb
set long loco address 0-10239
aaaa aaaa
10aa aaaa
80->b7
signal 1-2044 aspect 0-7, addr 0 not
valid
aaaa aaaa
01nn naaa
40->7f
accessory off(R) 1->2044, addr 0 not
valid
aaaa aaaa
0000 1aaa
08->0f
accessory on(N) 1->2044, addr 0 not
valid
aaaa aaaa
0000 0aaa
00->07
command string terminator - stop
execution
0000 0000
0000 0000
0x00
Command
2nd Byte
1st Byte
Hex
Key:
a - address bit, f - function bit, n - number, s - speed data, x - undefined
Notes:
Commands bf and c5 block reading/execution of all inputs until time expires
The wait commands of c6 block reading of all other inputs until condition is met
The “skip” commands of c6 work in “real time” (right now) and do not wait or block other
commands
Once the loco address is set all subsequent locomotive commands will be sent to that address.
Once the accy or signal address is set all subsequent OPs programming commands will be sent
to that address
Due to memory limitations the 0xbd,0xbe,0xc2, 0xc3, 0xc8 and 0xc6 function group 3
commands are not available through the ProCab setup interface. They are available for use
through the USB interface.
Last revised: 22 July 2008 Page 11