BURGLAR
Base number of zones
16
Maximum number of zones (expanded)
400
Total partitions*
64
Zone Characteristics/Options
19
Number of users
1800
Event Buffer
1000
User Profiles
100
* Each N-750 has 8 areas that can be divided into 8
sections for a total of 64 partitions. (See page 3 for more
information on partitions.)
ACCESS CONTROL
Number of doors
24
Number of touchpads
24 Supervised
Number of readers
24
Number of users
1800
ELECTRICAL
Accessory Power Supply (Source)
2.5 A
Optional Power Supply (Source)
2.5 A
Bell Power
1 A
Siren Driver
Yes
Electronic Overcurrent Protection
Yes
GENERAL
Programming
Touchpad/Software
Software Programmable
Yes
Memory
EEPROM
Answering Machine Bypass
Yes
Optional Printer Interface
Up to 8
DIGITAL COMMUNICATOR
Supported Formats
2
SIA Format
Yes
Contact ID
Yes
UL294 Access Control
Yes
UL Grade A
Yes
UL 365 Police Connect
Yes
UL 609 Local Burglary
Yes
UL 611 C.S. Burglary
Yes
UL 636 Holdup Alarm Units
Yes
UL 681 Bank Burg Systems
Yes
UL 864 Comm. Fire C.S. (DACT)
Yes
NFPA 72 (Chapter 4)
Yes
UL 985 Household Burglary
Yes
UL 1023 Household Burglary
Yes
UL 1076 Proprietary Burglary
Yes
UL 1610 C.S. Burglary
Yes
UL 1635 Digital Burglary Sys.
Yes
UL 1641 Instal. Res. Burglary
Yes
ULC Res./Comm. Burglary
Yes
FCC Part 15
Yes
FCC Part 68
Yes
DOC CS-03
Yes
CSFM Res./Comm/ Fire
Yes
CE Approved
Yes
Features
UL Approvals and Agency Listings
Compatible UL Listed Receivers
MANUFACTURER
RECEIVER MODEL
FORMATS
Silent Knight
Model 9000
SIA-1 (20 events per call)
Ademco
Model 685
Contact ID
Sur-Guard
SG-MLR2-DG
SIA-1, Contact ID
Osborne Hoffman
Quickalert
SIA-1, Contact ID
This system is rated for central fire station fire reporting only. It is not rated for life safety.