Northland Crown Royal 1000 Installation And Operation Instructions Manual

Manual is about: Pristine Series

Summary of Crown Royal 1000

  • Page 1

    Installation and operation instructions crown royal stoves pristine series model 1000

  • Page 3

    Table of contents pristine series installation and operation manual • 2011 1 introduction ......................................................................................................................................................... 3–4 the crown royal pristine series hot water furnace .....

  • Page 4

    Table of contents 2 pristine series installation and operation manual • 2011 operation cont’d ............................................................................................................................................ 18–20 cleaning out ash .............................................

  • Page 5

    Pristine series installation and operation manual • 2011 3 introduction the crown royal pristine series hot water furnace you have selected one of the best wood stoves/furnaces on the market today! It has been specially designed to produce highly efficient heat with emissions well below environmenta...

  • Page 6

    4 pristine series installation and operation manual • 2011 introduction model & serial number information locate and record the serial number in the space provided. See page 7 for location of decal on furnace. Have this information available when contacting the dealer for service, warranty or other ...

  • Page 7

    Safety pristine series installation and operation manual • 2011 5 • the pristine furnace is designed to work in conjunction with another heat source. We recommend this furnace not to be used as a stand alone unit. Should the system fail or run out of wood, a backup system must be in place. • for bes...

  • Page 8: Danger

    Safety 6 pristine series installation and operation manual • 2011 safety alert symbol the safety alert symbol identifies important safety messages in the manual and on the furnace. When this symbol is present, be alert to the possibility of injury or death. Follow all instructions in the safety mess...

  • Page 9

    Safety pristine series installation and operation manual • 2011 7 empyre elite hydronic furnace elite 100 #70211231 elite 100 #70211231 elite 100 #70211231 elite 100 #70211231 815835r00 815835r00 model no./modèle 100 serial no./ n° de série _________________________________ certifi ed heating applian...

  • Page 10

    Features 8 pristine series installation and operation manual • 2011 identifying main components (see list of components on page 9) 13 1 3 4 2 5 6 7 8 9 10 11 12 17 16 15 14 42 43 38 39 37 36 10 35 41 40 20 13 19 18 30 31 32 33 34 22 27 28 29 26 25 23 24 21 22 49 48 47 50 52 51 46 45 44.

  • Page 11

    Installation pristine series installation and operation manual • 2011 9 identifying main components (see drawings on page 8) no. Description 1 baffle 2 red indicator light 3 on/off switch 4 temperature control 5 loading door 6 latch catch 7 ash clean out door 8 ash tray 9 secondary burn chamber 10 h...

  • Page 12

    Installation 10 pristine series installation and operation manual • 2011 installation instructions we recommend that the furnace be installed by a qualified installer. 1. Identify and remove components shipped in the furnace firebox or rear of furnace: water level indicator, ash rake, flue cleaning ...

  • Page 13

    Installation pristine series installation and operation manual • 2011 11 supplying make up air fireplaces, other furnaces, clothes dryers, exhaust fans, and other appliances all draw air from the room in which they are located. The pristine furnace adds to that draw, making it important to ensure th...

  • Page 14

    Installation 12 pristine series installation and operation manual • 2011 important : the installation drawings in this manual are typical layouts shown as examples of types of layouts only. We recommend that you engage a professional plumbing and heating company to ensure your installation is suitab...

  • Page 15

    Installation pristine series installation and operation manual • 2011 13 hookup to existing heat system (water to air) 1. Install the circulating pump on the supply line and ensure that the pump’s motor is in a horizontal position. 2. Install the heat exchanger radiator in the hot air plenum of the ...

  • Page 16

    Installation 14 pristine series installation and operation manual • 2011 optional heat exchanger stainless steel water to water heat exchanger, figure 2, can be used in place of a side arm. Cold water mixed water tempering valve hot water used for bleeding air water heater use for filling system sup...

  • Page 17

    Installation pristine series installation and operation manual • 2011 15 a regular furnace system is left intact and automatically cuts in when the pristine indoor furnace runs out of wood, figure 3. Note: the existing furnace functions as a standby. The aquastat on the standby furnace should be tur...

  • Page 18

    Installation 16 pristine series installation and operation manual • 2011 baseboard distribution pool & spa hookup 24 v transformer thermostat line 1 indoor furnace circulating pump connected to furnace cord return to indoor furnace 3 way zone valve baseboard unit from indoor furnace figure 1 figure ...

  • Page 19

    Installation pristine series installation and operation manual • 2011 17 pool & spa hookup vent opening and water level indicator figure 3 keep the vent opening on top of the furnace clear of any obstructions. Important: 1. Use only soft, clean, filtered water in the pristine. Add northland distribu...

  • Page 20

    Operation 18 pristine series installation and operation manual • 2011 understanding the gasification process of the pristine wood furnace wood gasification is an amazingly clean burning and efficient process! It is a process where much of the solid fuel is converted to gases. These gases ignite and ...

  • Page 21

    Operation pristine series installation and operation manual • 2011 19 larger diameter and irregular shaped logs are more likely to cause wood to hang up or ‘bridge.’ it is best to mix larger logs with smaller logs. 3. Load wood into the firebox. Centre wood in the firebox. There should be a gap of s...

  • Page 22

    Operation 20 pristine series installation and operation manual • 2011 blower draft setting the blower and flapper unit flap opening settings are pre- determined by the factory and must not be altered. Altering these components could cause damage to the furnace and void the warranty. To replace any o...

  • Page 23

    Maintenance pristine series installation and operation manual • 2011 21 during heating season 1. Establish a daily routine for storage of fuel and care of the furnace. Check frequently for crusted ash buildup until experience shows how often cleaning is necessary. Be aware that the hotter the fire, ...

  • Page 24

    Reference 22 pristine series installation and operation manual • 2011 operating the digital temperature switch (dts) dts description the digital temperature switch is designed for many heating and cooling applications. The probe temperature (figure 1) is displayed on the bright 3-digit, red light em...

  • Page 25

    Reference pristine series installation and operation manual • 2011 23 caution do not connect the electrical components of this unit to any other electrical appliance..

  • Page 26

    Reference 24 pristine series installation and operation manual • 2011 furnace specifications - model 1000 heat output (peak)* 125,000 btu/hr 37.0 kw/hr heat output (8 hour burn)* 66,000 btu/hr 19.3 kw/hr heat output (12 hour burn)* 45,000 btu/hr 13.2 kw/hr furnace width 28 in 71 cm furnace height 48...

  • Page 27

    Troubleshooting pristine series installation and operation manual • 2011 25 problem possible cause solution blower will not come on. High limit switches may be shut off because the water temperature is higher than aquastat setting permits. Wait for the water to cool down. Reset snap disc, see page 8...

  • Page 28

    Troubleshooting 26 pristine series installation and operation manual • 2011 problem possible cause solution abnormal creosote buildup in the chimney and flue. Water temperature is often below 130°f (54°c) due to improper plumbing or too much heat draw. Pump must be hooked up to furnace pump electric...

  • Page 30: Crown Royal Stoves

    Warranty service may only be performed by northland distributing and manufacturing inc. Or a northland distributing authorized pristine furnace dealer or a northland distributing authorized pristine furnace service centre. Northland distributing and manufacturing inc. Warranty northland distributing...