Oasis Aquabar 2 Use & Care Manual - page 11
11
17. Let the reservoir and the hot tank (if applicable) fill. After 5 minutes, check to see that water flows easily from all taps
(see hot water safety instructions on page 3). IMPORTANT: You must wait until water has filled the hot tank
before plugging in the cooler to avoid overheating.
You can check for this by pressing the hot water dispense button
to see if any water flows out of the spout. Check for leaks.
18. Plug in the cooler. Push the “POWER” button to turn on the LCD display and power to the cooler for the LCD models.
19. Set up the cooler as desired using the setting functions described in a previous section.
TO REMOVE THE SIDE PANELS
1. Remove door by lifting out drip tray and pressing door latch down. Rectangular opening
under drip tray reveals door latch. Set door aside in a place where it won’t get scratched.
Put the drip tray back on the unit.
2. Remove the two screws holding the cabinet top on and lift the top up from the back. Set it
aside in a spot it won’t get scratched.
3. Each side panel is fastened at the front with a screw at top and bottom of the front panel.
The top screw is recessed into the panel notches.
4. There are two screws to remove in the back of each side panel.
5. Lift the panel up high enough to clear the plastic base, then slide it away from the unit.
There is a post near the center of the front panel that the side panel slides over (see
figure 6).
6. To put the side panels back on, follow this procedure in reverse, making sure the post
near the center of the front panel is fully engaged with the side panel. You may want
to steady the side panel with a hand at the bottom of it.
7. Make sure the ears at the bottom of the side panel are outside of the metal base
before trying to slide it down. The front ear has a notch to slide over a raised area
in the plastic base (see figure 7).
TO REMOVE THE FAUCET MANIFOLD
The center front panel under the dispense buttons is removable to get to the manifold.
It has a cut-away area centered at the top of the back side to facilitate removal (see
figure 8).
1. Press in slightly just above the center of the center front panel.
2. This will force the plastic of the button bracket to flex and reveal the finger notch in the center front panel.
3. Slide your finger down and pull out on the center front panel.
4. It will flex and then pull out completely.
5. Push the bonnet levers down to slide the rods to the side. The right and left rods (hot and cold respectively), should be
pushed through the groove running down the side.
6. The nozzle holds the manifold to the alcove. Unscrew it from the alcove area.
7. With the rods out of the way and the nozzle removed, lift up on the center of the manifold. Due to the seals for the
waterway, there will be some resistance.
8. To reassemble, remove the center front panel as described in steps 1-4 and place the manifold in through the opening.
You will need to slide it in with one of the hot or cold levers going first. Force the rod through the groove on the side
and slide the bonnet lever into the groove to keep it from popping back in the way. Slide the bonnet lever on the
opposite side in the same way.
9. Line up the threaded end of the manifold with the hole in the alcove. The stems for the hot and cold water will then line
up as well. Push the manifold down securely, working it through the alcove hole if the threads catch on the side.
10. Screw the nozzle back on and tighten it.
11. Push the bonnet levers down to slide the rods into the cup, and check proper activation by pushing the dispense buttons.
SERVICING THE UNIT
Figure 6
Figure 7
Figure 8