Oasis OASIS-30 User Manual - Model: Sf-102
8
1310836-07 | Mar 02 2016
MODEL: SF-102
AN ACCESS CODE IS NEEDED TO MODIFY PARAMETERS.
PLEASE CONTACT
MTL TECH SUPPORT TO RECEIVE YOUR
ACCESS CODE
1.888.685.8324
1
Set temperature (compressor stop temperature)
adjustment
• Press
SET button, the set temperature is displayed.
• Press ▲ or ▼ to modify and store the displayed values
• Press
SET button to exit the adjustment and display
the unit interior temperature.
• If idle for 10 or more seconds, the unit interior
temperature will be displayed.
2
Set the parameters
• Press
SET button, hold for 6 seconds to enter the
parameter setup mode while E1 flashes.
• Press
SET button again to toggle through the
parameters (see table below).
• Press ▲ or ▼ buttons, the value will be displayed and
can be modified and stored.
• If idle for 10 seconds the unit interior temperature will
be displayed.
FACTORY SETTINGS SF-102
Parameter
Function
Set Range
Factory Settings
S
Set Point
30-41 ºF / -1 to 5 ºC
26 ºF
E1
Lower set point limit
28 ºF / -45 ºC
24 ºF
E2
raise set point limit
41 ºF / 45 ºC
32 ºF
E3
Temperature Hysteresis
1~18 ºF / 1-10 ºC
3 ºF
E4
Comp. start delay time
0 ~ 10 min
4 min
E5
Offset on room temp.
-5 ~ 5 ºF / -5 to 5 ºC
0 ºF
E6
Offset on evap. temp.
-5 ~ 5 ºF / -5 to 5 ºC
0 ºF
F1
Max. frost duration
1~60 min
40 min
F2
Defrost interval time
0 ~ 24 hr
3 Hr
F3
Defrost termination temp.
32~68 ºF / 0~20 ºC
47 ºF
F4
Display during defrost
0=Norm. disp., 1=Last value before defrost
1 ºF
C1
Temperature unit
°C , °F
ºF
Controller Settings
Lighting
ON/OFF Switch
Cooler
ON/OFF Switch
CONTrOLLEr SETTINGS
Please verify the make and model of the controller before going forward.