Offshore 3185 User Manual

Manual is about: J1939 to NMEA2000 Adaptor

Summary of 3185

  • Page 1

    J1939 to nmea2000® adaptor part numbers: 3185 user manual revision 1.01.

  • Page 3

    1 of 12 1 introduction ........................................................2 1.1 firmware revision .............................................2 1.2 product features ...............................................2 2 installation ..........................................................3 2.1 u...

  • Page 4: Introduction

    Introduction 1 2 of 12 the offshore system’s nmea2000® 3185, j1939 to nmea2000® adaptor is designed to convert engine, transmission and generator messages on the j1939 network onto the nmea2000® network. This unit is designed to operate in a protected marine environment such as an engine room. It is...

  • Page 5: Installation

    Installation 2 3 of 12 2.1 unpacking the box you should find the following items in the 3185 shipping box: 1 x 3185 j1939 to nmea2000® adaptor 1 x din rail mounting kit with 2 rail mounts and 4 countersunk m3 screws for rails 1 x 3185 user manual (this document) 2.2 mounting the unit the unit can ei...

  • Page 6

    4 of 12 2.4 connecting the j1939 cable to the wago socket the cables from the power-source to the external sockets are connected using the wago cage clamp terminal block. The wire should be stripped for 8mm and then the cage clamp opened with a small screwdriver in the slot above the wire connection...

  • Page 7: Configuration

    Configuration 3 5 of 12 type pgn no parameters j1939 pgns pgn61443 engine percent load pgn61444 engine speed percent torque pgn65270 engine turbocharger boost pressure pgn65262 engine oil temperature engine coolant temperature pgn65271 alternator potential (voltage) pgn65266 engine fuel rate pgn6525...

  • Page 8

    6 of 12 pgn61445 transmission current gear pgn65272 transmission oil pressure transmission oil temperature pgn65030 generator average line to line voltage generator average line to neutral voltage generator average frequency generator average current type pgn no parameters periodic data pgns pgn1274...

  • Page 9

    7 of 12 parameter value iec 60954 classification protected degree of protection ip40 operating temperature -25°c to 50°c storage temperature -40°c to 70°c relative humidity 93%rh @40° per iec60945-8.2 vibration 2-13.2hz @ ±1mm, 13.2-100hz @ 7m/s2 per iec 60945-8.7 environmental.

  • Page 10: Warranty

    Warranty 4 8 of 12 8 of 12 offshore systems warrants this product to be free from defects in materials and workmanship for one year from the date of original purchase. If within the applicable period any such products shall be proved to offshore systems satisfaction to fail to meet the above limited...

  • Page 11: Technical Support

    Technical support 5 9 of 12 9 of 12 if you require technical support for any offshore systems products you can reach us using any of the following ways: ● tel: +44(0)1425 610022 ● fax: +44(0)1425 614794 ● email: support@osukl.Com ● web: www.Osukl.Com ● post: offshore systems uk ltd unit 10-11 milton...

  • Page 12: E Sy

    10 of 12 of fs h or e sy st em s p rod u c t m a p 8.