2.4 Connecting the J1939 cable to the WAGO socket
The cables from the power-source to the external sockets are connected using the WAGO Cage
Clamp terminal block. The wire should be stripped for 8mm and then the cage clamp opened
with a small screwdriver in the slot above the wire connection. Then simply insert the wire into
it’s connection slot and release the cage clamp by removing the small screw driver. This will
produce a secure gas tight connection on wire sizes from 0.08 – 1.5 mm²
2.5 J1939 Connections
The terminal connections are numbered as follows:
These are marked on the unit case.
Terminal 1
CAN H (HIGH-level J1939 CAN bus line)
Terminal 2
Ground
Terminal 3
CAN L (LOW-level J1939 CAN bus line)