  • Page 1

    Valor 2000 series tm instruction manual 99 washington street melrose, ma 02176 phone 781-665-1400 toll free 1-800-517-8431 visit us at www.Testequipmentdepot.Com.

  • Page 3: En-1

    En-1 valor 2000 series scales 1. Introduction this manual contains installation, operation and maintenance instructions for the valor 2000 series scales. Please read the manual completely before using the scale. Tm 1.1 safety precautions please follow these safety precautions: • verify that the ac a...

  • Page 4: En-2 Valor 2000

    En-2 valor 2000 series scales table 1-1. Control functions. Button primary function (short press) on/ 0/t turns scale on. If scale is on: sets zero. Performs a tare operation. Units changes the weighing unit. Secondary function (long press) off turns scale off. Menu enter the user menu. Menu functio...

  • Page 5: En-3

    En-3 valor 2000 series scales level bubble adjustable feet figure 2-1. Leveling the scale. Important: to relieve any internal pressure and allow proper airflow inside the scale, unscrew the two rear leveling feet slightly, then level the scale accordingly. When cleaning the scale, the rear leveling ...

  • Page 6: En-4 Valor 2000

    En-4 valor 2000 series scales 2.4.2 battery power the scale can be operated on the internal rechargeable battery when ac power is not available. The scale will automatically switch to battery operation if there is a power failure or the power cord is removed. Before using the scale for the first tim...

  • Page 7: En-5

    En-5 valor 2000 series scales 2.5 initial calibration when the scale is operated for the first time, a span calibration is recommended to ensure accurate weighing results. Before performing the calibration, be sure to have the appropriate calibration weight. Refer to section 4.2 for span calibration...

  • Page 8: En-6 Valor 2000

    En-6 valor 2000 series scales 4.2 cal menu span perform span calibration yes or no. Lin perform linearity calibration yes or no. Note: • ensure the appropriate calibration masses are available before beginning calibration (see table 4-1). • ensure that the scale is level and stable during the entire...

  • Page 9: En-7

    En-7 valor 2000 series scales the display flashes the span calibration point. Place the specified weight on the scale and press the yes button. To choose a different span point, repeatedly press the no button to increment the selections. When the desired value is displayed, place the specified weigh...

  • Page 10: En-8 Valor 2000

    En-8 valor 2000 series scales the display flashes the full calibration point. Place the specified weight on the scale and press the yes button. The display shows --c-- while the full calibration point is established. If linearity calibration was successful, done is displayed and the scale exits to t...

  • Page 11: En-9

    En-9 valor 2000 series scales 4.5 a off menu auto shut off set the automatic shut off to 5, 10, 15 minutes (shut off after 5 minutes, etc.) or off (scale stays on). 4.6 filtr menu filtering level set the filter level to lo (low), med (medium), or hi (high). 4.7 azt menu auto zero tracking range set ...

  • Page 12: En-10 Valor 2000

    En-10 valor 2000 series scales figure 5-1. Lock switch. Lock switch when accessing the bottom of the scale, avoid placing the scale upside down on the pan or sub-platform. Place the scale on its side. 5.2 verification before this product can be used in a trade approved application, it must be inspec...

  • Page 13: En-11

    En-11 valor 2000 series scales 6.1 cleaning the housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panels. 6.2 troubleshooting the following table lists common problems and pos...

  • Page 14: En-12 Valor 2000

    En-12 valor 2000 series scales 6.3 service information if the troubleshooting section does not resolve or describe your problem, contact your authorized ohaus service agent. For service assistance or technical support in the united states call toll-free 1-800-526-0659 between 8.00 am and 5:00 pm est...

  • Page 15: En-13

    En-13 valor 2000 series scales 7.2. Drawings and dimensions 249 mm (9.8 in.) 229 mm (9.0 in.) 233 mm (9.2 in.) 184 mm (7.2 in.) 142 mm (5.6 in.) figure 7-1. Valor 2000 series overall dimensions..

  • Page 16: En-14 Valor 2000

    En-14 valor 2000 series scales 7.3. Compliance compliance to the following standards is indicated by the corresponding mark on the product. Mark standard this product conforms to the emc directive 2004/108/ec and the low voltage directive 2006/95/ec. The complete declaration of conformity is availab...

  • Page 17: En-15

    En-15 valor 2000 series scales disposal in conformance with the european directive 2002/96 ec on waste electrical and electronic equipment (weee) this device may not be disposed of in domestic waste. This also applies to countries outside the eu, per their specific requirements. Please dispose of th...

  • Page 18: En-16 Valor 2000

    En-16 valor 2000 series scales limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to be...