6.7.3. Adaptive function
Here you can activate/deactivate (On/Off) the
adaptive function. This function is only related
to the 4-event timer and only works in
connection with going from one event to
another where the temperature is going to be
raised. The adaptive function finds out when the
thermostat shall start heating to ensure that the
right temperature is reached at the time that it
has been programmed for.
6.7.4. Offset
Offset is used to compensate for any difference
between the thermostat and a room
thermometer. If the thermometer, for instance,
shows 1°C more than the thermostat, it is
possible to adjust the offset by +/- 5°C. Then
the thermostat will show the same temperature
as the thermometer. If the thermostat for
example shows 1 degree too much, offset
should be set to +1. Then the temperature will
be set 1 degree lower.
Offset applies to both built-in and external
sensors whereas the limit sensor, if any, is not
affected.
6.7.6. Reset
• Reset 2: Reset values defined in Engineer
settings to factory settings.
• Reset 3: Equal to Reset 2, except history
data are deleted. The number of relay
connections is not deleted, though.
7. Error Messages
If you get an error the LED is flashing red.
Internal failure The thermostat is defective,
replace thermostat
External failure External sensor or heating
unit is defective.
4
Day 1-5
Event
Time
With floor sensor
With air sensor
Day
06:00-08:00
25°C
20°C
Out
08:00-16:00
20°C
15°C
Home
16:00-22:30
25°C
22°C
Night
22:30-06:00
20°C
15°C
Day 6-7
Event
Time
With floor sensor
With air sensor
Day
08:00-23:00
25°C
22°C
Night
23:00-08:00
20°C
15°C
8. Factory settings
The thermostat is delivered with factory set programs as follows:
Tiles
Stone
Laminate
Wood
Carpet
Vinyl
Other
Undertile
YES
YES
NO
NO
NO
NO
YES
Underlaminate
NO
NO
YES
YES
NO
NO
YES
Undercarpet
NO
NO
YES
YES
YES
YES
YES
Inscreed
YES
YES
YES
YES
YES
YES
YES
Type A
YES
YES
NO
NO
NO
NO
YES
Type B
NO
NO
NO
NO
YES
YES
YES
User Defined
YES
YES
YES
YES
YES
YES
YES
Tiles
Stone
Laminate
Wood
Carpet
Vinyl
Other
Undertile
A
A
n/a
n/a
n/a
n/a
E
Underlaminate
n/a
n/a
B
B
n/a
n/a
E
Undercarpet
n/a
n/a
B
B
C
C
E
Inscreed
A
A
B
B
C
C
E
Type A
D
D
n/a
n/a
n/a
n/a
E
Type B
n/a
n/a
n/a
n/a
C
C
E
User Defined
E
E
E
E
E
E
E
Configuration
Control temperature
Overheat
Room
Floor
Min. Max.
Min. Max.
Max.
A
5
30
5
40
40
B
5
27
5
27
27
C
5
25
5
25
27
D
5
30
5
50
55
E
prog
prog
prog
9. Appendix
9.1. Table of Compatibility
9.2. Heat Definitions
n/a = not available