5.2.3.2
Rudimentary
adjustment of focus
Procedures:
Manually feed the specified pattern of the test chart,
test chart (see
Figure
until it is set at the reading position.
Loosen the lens lock screw.
Move the lens back and forth, in the direction of the symbol “F”, to maximize the
output level difference.
Lens
Lens Lock
Screw
Fig. 5.2.8 Focus adjustment
Fig. 5.2.9
Rudimentary
focus
adjustment waveform
q
m m m m m m m m m
Fig. 5.2.10
Part of the
test chart
5 - 1 7