Pacific AMX series Operation Manual - page 20
SECTION 2 SPECIFICATIONS
10
MODEL 305-AMX
INPUT VOLTAGE
The Model 305-AMX accepts one of the following single phase input voltages:
1)
110 VAC ±10%, 47-63 Hz (360-440 Hz optional)
2)
120 VAC ±10%, 47-63 Hz (360-440 Hz optional)
3)
220 VAC ±10%, 47-63 Hz (360-440 Hz optional)
4)
230 VAC ±10%, 47-63 Hz (360-440 Hz optional)
5)
240 VAC ±10%, 47-63 Hz (360-440 Hz optional)
INPUT CURRENT
The input current required by the Model 305-AMX at full rated load is stated below. Recommended input
service is also stated.
V
in
INPUT CURRENT
1)
110 VAC
9 A
rms
; 20 A Service Recommended
2)
120 VAC
8 A
rms
; 20 A Service Recommended
3)
220 VAC
5 A
rms
; 15 A Service Recommended
4)
230 VAC
4 A
rms
; 15 A Service Recommended
5)
240 VAC
4 A
rms
; 15 A Service Recommended
MODEL 308-AMX
INPUT VOLTAGE
The Model 308-AMX accepts one of the following single phase input voltages:
1)
110 VAC ±10%, 47-63 Hz (360-440 Hz optional)
2)
120 VAC ±10%, 47-63 Hz (360-440 Hz optional)
3)
220 VAC ±10%, 47-63 Hz (360-440 Hz optional)
4)
230 VAC ±10%, 47-63 Hz (360-440 Hz optional)
5)
240 VAC ±10%, 47-63 Hz (360-440 Hz optional)
INPUT CURRENT
The input current required by the Model 308-AMX at full rated load is stated below. Recommended input
service is also stated.
V
in
INPUT CURRENT
1)
110 VAC
14 A
rms
; 20 A Service Recommended
2)
120 VAC
13 A
rms
; 20 A Service Recommended
3)
220 VAC
7 A
rms
; 15 A Service Recommended
4)
230 VAC
7 A
rms
; 15 A Service Recommended
5)
240 VAC
6 A
rms
; 15 A Service Recommended