Pacific Energy FP30AR Installation And Operating Instructions Manual

Manual is about: ZERO CLEARANCE WOOD FIREPLACE B series

Summary of FP30AR

  • Page 1

    120216-32 fp30, fp30ar 5055.5152 installation and operating instructions safety notice if this fireplace is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection ...

  • Page 2: Contents

    2 fp30 b 120216-32 ©pacific energy fireplace products ltd. Contents safety and maintenance .............................................................. 3 maintenance checks ................................................................... 4 baffle removal ...........................................

  • Page 3

    3 ©pacific energy fireplace products ltd. Safety and maintenance note: we strongly recommend that smoke and carbon monoxide detectors be installed in the area where the heater is to be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequentl...

  • Page 4

    4 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placem...

  • Page 5

    Fp30 b 120216-32 5 ©pacific energy fireplace products ltd. Fig. #4 nuts fig. #1 fig. #2 fig. #3 bolts wingnuts to switch or speed controller screws blower replacement note: disconnect power before proceeding 1. The blowers are located in the bottom rear compartment of the fireplace and can be access...

  • Page 6

    6 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other or- ganic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As ...

  • Page 7

    Fp30 b 120216-32 7 ©pacific energy fireplace products ltd. Operation caution: hot while in operation. Keep children, clothing and furniture away. Contact will cause skin burns. Warning: over firing the appliance will short- en the life of the product. Failure to rectify an over firing condition can ...

  • Page 8

    8 ©pacific energy fireplace products ltd. Warning: no alteration or modification of the combus- tion air control assembly is permitted. Any tampering will void warranty and could be very hazardous. Warning: do not use grates or andirons to elevate the fuel. Burn directly on the fire bricks. Replace ...

  • Page 9

    Fp30 b 120216-32 9 ©pacific energy fireplace products ltd. Item size part number a 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 b 9” x 3 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 3245.501 c 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 firebrick installation this package contain...

  • Page 10

    10 ©pacific energy fireplace products ltd. Fireplace installation crate removal 1) carefully remove wood top and supports. 2) remove the screws securing the fireplace to the pallet(4). 3) remove from pallet bottom. Under no circumstances is this heater to be installed in a makeshift or "temporary" m...

  • Page 11

    Fp30 b 120216-32 11 ©pacific energy fireplace products ltd. Fp30 & fp30ar 42" [1.07m] 47" [1.19m] 30 3/4" [781mm] 9 5/8" [245mm] 34 7/8" [886mm] 23" [584mm] 27 1/2" [699mm] 13 1/4" [337mm] 23 7/8" [606mm] 30 1/8" [765mm] dimensions procedure: the fireplace should be in place before framing. Note: se...

  • Page 12

    12 ©pacific energy fireplace products ltd. 24" 610mm 35 5/8 " 905mm 103 1/4 " 2.62m 25 1/4 " 641mm 56" 1.42m 63 1/2 " 1.61m 5 3/8 " 137mm 73" 1.85m 73" 1.85m 56" 1.42m 56" 1.42m 1"(25mm) distance from unit to rear wall 16” 406mm minimum framing dimensions fig. #7 note: the framing dimensions around ...

  • Page 13

    Fp30 b 120216-32 13 ©pacific energy fireplace products ltd. Item part # description qty. 1 5049.9912 screw, teks pkg #8 x 1/2”(13mm) 40 2 7746 stud, top/bottom 55 3/4”(1.42m)l 2 3 9093.22 stud, cntr support sides, 15”(381mm)l 5 4 7747 framing kit leg 3 1/2"(89mm)l 3 framing kit assembly 2 3 each kit...

  • Page 14

    14 ©pacific energy fireplace products ltd. Fig. #9 chimney roof flashing storm collar spark arrestor rain cap radiation shield chimney support 37" (940mm) minimum distance from unit to ceiling minimum 7' (2.1m) ceiling height non-combustible floor protector note: maximum unsupported chimney height i...

  • Page 15

    Fp30 b 120216-32 15 ©pacific energy fireplace products ltd. Chimney installation listed chimney this appliance must be installed with a 6"(150mm) chimney system approved under the following standards: can-ulc s629(in canada) and ul 103ht(in u.S.). You must follow the chimney manufacturer's installat...

  • Page 16

    16 ©pacific energy fireplace products ltd. Offsets 30° or 45° elbows the chimney for the fp30 can be installed with a maximum of four 45° elbows(in canada) and four 30° elbows(in u.S.A.) as shown in fig. #10. Installation: 1. Install the first elbow; turn it in the required direction. It is required...

  • Page 17

    Fp30 b 120216-32 17 ©pacific energy fireplace products ltd. Combustion air intake or combustion air can be supplied to the fireplace in one of two ways. Consult your local building code or can/csa- b365, installation code for solid-fuel-burning appliances and equipment before proceeding. Note: outsi...

  • Page 18

    18 ©pacific energy fireplace products ltd. 18" [457mm] 8" [203mm] 8" [203mm] 19 1/8" [486mm] 38 7/8" [987mm] 18" [457mm] 8" [203mm] 8" [203mm] 58" [1.47m] canada only floor protector the fireplace may be installed on a combustible floor provided non-combustible ember protection with a k value of 23....

  • Page 19

    Fp30 b 120216-32 19 ©pacific energy fireplace products ltd. 48 1/8”min 1.22m air inlet 12” min 305mm from outer edge of grill to any ceiling or wall. 36”(914mm)min. From the floor. Remote heat duct installation part# wodc.Rhka note: the chase enclosure must have a 30in² (194 cm²) air inlet. (in u.S....

  • Page 20

    20 ©pacific energy fireplace products ltd. Fig. #18 2. Insert a remote heat flap box in the opening/s that you are attaching a kit to. Attach the heat duct adapter/s with the screws provided in the wodc.Rhka (fig. #17). 3. Locate the remote blower assembly in the desired wall or ceiling location, ma...

  • Page 21

    Fp30 b 120216-32 21 ©pacific energy fireplace products ltd. Round duct (6”(150mm) type ”b”) maximum duct length 20’(6.1m). Chimney installtions not shown.

  • Page 22

    22 ©pacific energy fireplace products ltd. Cement board installation the front facing area of the fp30 must be covered with non- combustible cement board as shown in fig.#20 and #21 prior to applying any finishing material. The cement board can be attached to the framing and to the front of the unit...

  • Page 23: Combustible Mantle

    Fp30 b 120216-32 23 ©pacific energy fireplace products ltd. Fig. #22 7’(2.13m) floor to ceiling minimum (b) 51" 1.3m (b) 55" 1.4m (a)4"(102mm) (a) 12"(305mm) combustible mantle graduated mantle depth (a) height from base of unit (b) 4"(102mm) 51"(1.3m) 5"(127mm) 51 1/2"(1.31m) 6"(150mm) 52"(1.32m) 7...

  • Page 24

    24 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / o...

  • Page 25

    Fp30 b 120216-32 25 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned firewood, up to 20" long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1" minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. A...

  • Page 26

    26 ©pacific energy fireplace products ltd. Replacement parts item description part no. 1............Inlet air grill .......................................... Fp30.77223 2............Cast ash lip ....................................Alip.50374753 3............Blowers.....................................

  • Page 27

    Fp30 b 120216-32 27 ©pacific energy fireplace products ltd. Warranty information pacific energy limited lifetime warranty wood products pacific energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime covera...

  • Page 28

    28 ©pacific energy fireplace products ltd. Fp30 b 120216-32.

  • Page 29

    Fp30 b 120216-32 29 ©pacific energy fireplace products ltd..

  • Page 30

    30 ©pacific energy fireplace products ltd. Fp30 b 120216-32.

  • Page 31: Caution

    Fp30 b 120216-32 31 ©pacific energy fireplace products ltd. Label le systÈme de cheminÉe doit Être homologuÉ comme suit : au canada - cheminÉe homologuÉe ulc-s-629, aux États-unis - cheminÉe homologuÉe ul-103 ht. • installez et utilisez selon les instructions d’installation et d’utilisation fournies...

  • Page 32

    ?pacific energy fireplace products ltd. Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 web site: http://www.Pacificenergy.Net printed in canada.