Pacific Energy FP30AR Installation And Operating Instructions Manual

Manual is about: ZERO CLEARANCE WOOD FIREPLACE B series

Summary of FP30AR

  • Page 1

    261114-28 fp30, fp30ar 5055.5152 installation and operating instructions safety notice if this fi replace is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspecti...

  • Page 2: Contents

    2 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Note: we strongly r e c o m m e n d t h at smoke detectors be installed. If smoke detectors have been previ- ously installed, you may notice that they are operating more frequently. This may be due to curing of fi replace paint or fume...

  • Page 3

    Pacific fp30 261114-28 3 ©pacific energy fireplace products ltd. Safety and maintenance 1. Burn only, dry and well seasoned cord wood. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, it will red...

  • Page 4

    4 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door g...

  • Page 5

    Pacific fp30 261114-28 5 ©pacific energy fireplace products ltd. Fig. #4 nuts fig. #1 fig. #2 fig. #3 bolts wingnuts to switch or speed controller screws blower replacement note: disconnect power before proceeding 1. The blowers are located in the bottom rear compartment of the fi replace and can be...

  • Page 6

    6 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Creosote formation and need for removal when wood is burned slowly, it produces tar and other or- ganic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue ...

  • Page 7

    Pacific fp30 261114-28 7 ©pacific energy fireplace products ltd. Operation caution: hot while in operation. Keep children, clothing and furniture away. Contact will cause skin burns. Warning: over firing the appliance will short- en the life of the product. Failure to rectify an over firing conditio...

  • Page 8

    8 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Amount of wood in lbs. X 7500btu’s burn rate in hrs. X .8(80% avg. Efficiency) over firing over fi ring can be caused by operating the unit with the door open, damage to door gaskets allowing excess air to enter the fi rebox, the use o...

  • Page 9

    Pacific fp30 261114-28 9 ©pacific energy fireplace products ltd. Item size part number a 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 b 9” x 3 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 3245.501 c 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 firebrick installation this package c...

  • Page 10

    10 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Fireplace installation crate removal 1) carefully remove wood top and supports. 2) remove the screws securing the fi replace to the pallet(4). 3) remove from pallet bottom. Warning: under no circumstances is this heater to be installe...

  • Page 11

    Pacific fp30 261114-28 11 ©pacific energy fireplace products ltd. Fp30 & fp30ar 42" [1.07m] 47" [1.19m] 30 3/4" [781mm] 9 5/8" [245mm] 34 7/8" [886mm] 23" [584mm] 27 1/2" [699mm] 13 1/4" [337mm] 23 7/8" [606mm] 30 1/8" [765mm] dimensions procedure: the fi replace should be in place before framing. N...

  • Page 12

    12 pacific fp30 261114-28 ©pacific energy fireplace products ltd. 24" 610mm 35 5/8 " 905mm 103 1/4 " 2.62m 25 1/4 " 641mm 56" 1.42m 63 1/2 " 1.61m 5 3/8 " 137mm 73" 1.85m 73" 1.85m 56" 1.42m 56" 1.42m 1"(25mm) distance from unit to rear wall minimum framing dimensions fig. #7 note: the framing dimen...

  • Page 13

    Pacific fp30 261114-28 13 ©pacific energy fireplace products ltd. Item part # description qty. 1 5049.9912 screw, teks pkg #8 x 1/2”(13mm) 40 2 7746 stud, top/bottom 55 3/4”(1.42m)l 2 3 9093.22 stud, cntr support sides, 15”(381mm)l 5 4 7747 framing kit leg 3 1/2"(89mm)l 3 framing kit assembly 2 3 ea...

  • Page 14

    14 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Fig. #9 chimney roof fl ashing storm collar spark arrestor rain cap radiation shield chimney support 37" (940mm) minimum distance from unit to ceiling minimum 7' (2.1m) ceiling height non-combustible fl oor protector note: maximum uns...

  • Page 15

    Pacific fp30 261114-28 15 ©pacific energy fireplace products ltd. Chimney installation listed chimney this appliance must be installed with a 6"(150mm) chimney system approved under the following standards: can-ulc s629(in canada) and ul 103ht(in u.S.). You must follow the chimney manufacturer's ins...

  • Page 16

    16 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Offsets 30° or 45° elbows the chimney for the fp30 can be installed with a maximum of four 45° elbows(in canada) and four 30° elbows(in u.S.A.) as shown in fig. #10. Installation: 1. Install the fi rst elbow; turn it in the required d...

  • Page 17

    Pacific fp30 261114-28 17 ©pacific energy fireplace products ltd. Combustion air intake or combustion air can be supplied to the fi replace in one of two ways. Consult your local building code or can/csa- b365, installation code for solid-fuel-burning appliances and equipment before proceeding. Note...

  • Page 18

    18 pacific fp30 261114-28 ©pacific energy fireplace products ltd. 18" [457mm] 8" [203mm] 8" [203mm] 19 1/8" [486mm] 38 7/8" [987mm] 18" [457mm] 8" [203mm] 8" [203mm] 58" [1.47m] canada only floor protector the fi replace may be installed on a combustible fl oor provided non-combustible ember protect...

  • Page 19

    Pacific fp30 261114-28 19 ©pacific energy fireplace products ltd. 55”min 1.4m gravity vent air inlet 12” min 305mm from outer edge of grill to any floor, ceiling or wall remote heat duct installation part# wodc.Rhka note: the chase enclosure must have a 30in2 (194 cm2) air inlet. (in u.S.A. And cana...

  • Page 20

    20 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Fig. #18 3. Locate the remote blower assembly in the desired wall or ceiling location, maximum 20’(6.1m) away from the unit, and secure to the framing. Note: the remote heat kit blower/s can be installed so that any edge of the grill ...

  • Page 21

    Pacific fp30 261114-28 21 ©pacific energy fireplace products ltd. Round duct (6”(150mm) type ”b”) maximum duct length 20’(6.1m). Chimney installtions not shown.

  • Page 22

    22 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Cement board installation the front facing area of the fp30 must be covered with non- combustible cement board as shown in fig.#20 and #21 prior to applying any fi nishing material. The cement board can be attached to the framing and ...

  • Page 23: Combustible Mantle

    Pacific fp30 261114-28 23 ©pacific energy fireplace products ltd. Fig. #22 7’(2.13m) floor to ceiling minimum (b) 51" 1.3m (b) 55" 1.4m (a)4"(102mm) (a) 12"(305mm) combustible mantle graduated mantle depth (a) height from base of unit (b) 4"(102mm) 51"(1.3m) 5"(127mm) 51 1/2"(1.31m) 6"(150mm) 52"(1....

  • Page 24

    24 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper...

  • Page 25

    Pacific fp30 261114-28 25 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned fi rewood, up to 20" long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1" minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold s...

  • Page 26

    26 pacific fp30 261114-28 ©pacific energy fireplace products ltd. Replacement parts item description part no. 1............ Inlet air grill .......................................... Fp30.77223 2............ Cast ash lip .................................... Alip.50374753 3............ Blowers..........

  • Page 27: Caution

    Pacific fp30 261114-28 27 ©pacific energy fireplace products ltd. Label le systÈme de cheminÉe doit Être homologuÉ comme suit : au canada - cheminÉe homologuÉe ulc-s-629, aux le systÈme de cheminÉe doit Être homologuÉ comme suit : au canada - cheminÉe homologuÉe ulc-s-629, aux États-unis - cheminÉe ...

  • Page 28